{"title":"Ipari műszerek","description":"\u003cp\u003eIpari, PLC-kompatibilis Atlas Scientific mérőszondák és transzmitterek.\u003c\/p\u003e","products":[{"product_id":"industrial-pt-1000-temperature-probe-2","title":"Industrial PT-1000 Temperature Probe","description":"\u003cp\u003eThe Industrial PT-1000 Temperature Probe is a high-accuracy 4-wire temperature sensor. Internally it uses a class A PT-1000 platinum resistance temperature detector. The sensor is food safe and can be screwed into a pipe or a tank using its 3\/4″ NPT threading. The sensor can be used in 2, 3, or 4 wire temperature sensor applications.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass A platinum, RTD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-55 ̊C to 220 ̊C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- (0.15 + (0.002*t))\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReaction Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90% in 13s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 Meters (10′)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSMA or Tinned leads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eResistance (Analog)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLife expectancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Industrial-pt-1000-probe.pdf\" target=\"_blank\" rel=\"noopener\"\u003eIndustrial PT-1000 Temperature Probe Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRoHS Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/csa-certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCSA Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"Tinned Lead","offer_id":58589152837964,"sku":"ENV-50–TMP","price":27841.5,"currency_code":"HUF","in_stock":true},{"title":"Male SMA","offer_id":58589152870732,"sku":"ENV-50–TMP-SMA","price":30590.0,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/ENV-50-TMP-main-2.jpg?v=1787830693"},{"product_id":"industrial-conductivity-probe-k-1-0-2","title":"Industrial Conductivity Probe K 1.0","description":"\u003cp\u003eThe Atlas Scientific Industrial Conductivity Probe K 1.0 is a rugged, high-performance sensor designed for accurate conductivity measurements across a wide range of applications. Ideal for environments such as chemical processing and water quality monitoring, it delivers stable, reliable readings even under demanding conditions. The probe features a durable 3\/4″ NPT threaded body for easy installation and an integrated PT-1000 temperature sensor for precise temperature compensation. Its electrolyte-free design reduces maintenance needs and supports long-term operation, with calibration typically required only during installation and a lifespan that can extend up to a decade.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConductivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 − 200,000μS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/ – 2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90% in 1s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature range °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 − 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e141m (463 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSMA or Tinned leads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 meters (10′)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal temperature sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes (PT-1000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTime before recalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLife expectancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/IEC_probe-K1.0.pdf\" target=\"_blank\" rel=\"noopener\"\u003eIndustrial Conductivity Probe K 1.0 Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/legacy-IEC_probe-K1.0.pdf\" target=\"_blank\" rel=\"noopener\"\u003eLEGACY Industrial Conductivity Probe K 1.0 Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/connecting-probes-into-a-pipe.pdf\" target=\"_blank\" rel=\"noopener\"\u003eConnecting probes into a pipe\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRoHS Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/csa-certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCSA Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"Tinned Leads","offer_id":58589152936268,"sku":"ENV-50\u0026#8211;EC-K1.0","price":117656.5,"currency_code":"HUF","in_stock":true},{"title":"SMA","offer_id":58589152969036,"sku":"ENV-50\u0026#8211;EC-K1.0-SMA","price":121578.0,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/iec-probe-k1.0-main.jpg?v=1787830694"},{"product_id":"industrial-dissolved-oxygen-probe-2","title":"Industrial Dissolved Oxygen Probe","description":"\u003cp\u003eWhen you need long term readings from a probe that’s almost impossible to break, the Atlas Scientific Industrial Dissolved Oxygen probe is what you need. The probe holds a lot of electrolyte so it will last for a long time before needing reconditioning. The built-in PT-1000 temperature sensor and threaded body reduces the need for excess parts and makes it easy to install in a pipe.\u003c\/p\u003e\n\u003cp\u003eEach probe comes with its own unique 12-digit serial number for tracking and traceability.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eUnique 12-digit serial number\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDissolved Oxygen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 − 100 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/– 0.05 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~0.1 mg\/L\/per sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature range °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 − 99 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e212m (694 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSMA or Tinned leads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 Meters (10′)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal temperature sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes (PT-1000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTime before recalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLife expectancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~4 Years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaintenance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~18 Months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Industrial-DO-probe.pdf\" target=\"_blank\" rel=\"noopener\"\u003eIndustrial Dissolved Oxygen Probe Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/connecting-probes-into-a-pipe.pdf\" target=\"_blank\" rel=\"noopener\"\u003eConnecting probes into a pipe\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRoHS Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/csa-certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCSA Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ENV-50-DO.zip\" target=\"_blank\" rel=\"noopener\"\u003eENV-50-DO 3D model (*step)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"SMA","offer_id":58589153034572,"sku":"ENV-50\u0026#8211;DO","price":133342.5,"currency_code":"HUF","in_stock":true},{"title":"Tinned Leads","offer_id":58589153067340,"sku":"ENV-50\u0026#8211;DO","price":129421.0,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/env-50-do-main-06.jpg?v=1787830694"},{"product_id":"industrial-ph-probe-2","title":"Industrial pH Probe – with Temp","description":"\u003cp\u003eDesigned for industrial process control, the Atlas Scientific industrial pH probe has all the capabilities of our lab-grade pH probe and more!\u003c\/p\u003e\n\u003cp\u003eBecause the probe is larger, it holds more internal electrolyte. This means it has a life expectancy almost twice as long as our Lab Grade probe. Its thick Ryton body is chemically inert and virtually indestructible. Unlike traditional pH probes that have a glass bulb at its tip, this probe has a flat sensing area. That means that you never have to worry about the glass breaking off into your liquid. And we didn’t even mention the 3\/4″ NPT threaded body or internal temperature sensor!\u003c\/p\u003e\n\u003cp\u003eEach probe comes with its own unique 12-digit serial number for tracking and traceability.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eDouble junction\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003esilver \/ silver chloride\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eUnique 12-digit serial number\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 − 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% in 1s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature range °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 − 99 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70m (230 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSMA or Tinned leads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 meters (10′)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal temperature sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes (PT-1000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTime before recalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLife expectancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~4 Years +\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/IpH_probe_with_temp.pdf\" target=\"_blank\" rel=\"noopener\"\u003epH Industrial Probe with Temp Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/connecting-probes-into-a-pipe.pdf\" target=\"_blank\" rel=\"noopener\"\u003eConnecting probes into a pipe\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRoHS Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/csa-certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCSA Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/atlas-scientific.com\/ph-temperature-calculator\/\" target=\"_blank\" rel=\"noopener\"\u003epH Temperature Compensation Calculator\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ENV-50-pH.zip\" target=\"_blank\" rel=\"noopener\"\u003eENV-50-pH 3D model (*step)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"Tinned Leads","offer_id":58589153165644,"sku":"ENV-50\u0026#8211;pH","price":125499.5,"currency_code":"HUF","in_stock":true},{"title":"SMA","offer_id":58589153198412,"sku":"ENV-50\u0026#8211;pH-SMA","price":129421.0,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/ENV-50-pH-main-3_8e557a73-9d43-4f55-ae2e-c31e18f67522.jpg?v=1787830694"},{"product_id":"industrial-orp-probe-2","title":"Industrial ORP Probe","description":"\u003cp\u003eThe Atlas Scientific industrial ORP probe is built to last. It has all the sensing capabilities of our lab-grade probe in a virtually indestructible housing. The 3\/4″ NPT threaded body makes it easy to screw into a pipe, perfect for chemical production or swimming pool monitoring.\u003c\/p\u003e\n\u003cp\u003eEach probe comes with its own unique 12-digit serial number for tracking and traceability.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eUnique 12-digit serial number\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eORP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-2000mV – 2000mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/– 1mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% in 1s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensing element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlatinum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature range °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 − 99 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70m (230 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSMA or Tinned leads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 meters (9.8′)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal temperature sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTime before recalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLife expectancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~4 Years +\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/IORP_probe.pdf\" target=\"_blank\" rel=\"noopener\"\u003eIndustrial ORP Probe Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/connecting-probes-into-a-pipe.pdf\" target=\"_blank\" rel=\"noopener\"\u003eConnecting probes into a pipe\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRoHS Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/csa-certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCSA Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ENV-50-ORP.zip\" target=\"_blank\" rel=\"noopener\"\u003eENV-50-ORP 3D model (*step)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"3 meters (9.8') SMA","offer_id":58589153427788,"sku":"ENV-50\u0026#8211;ORP-SMA","price":109813.5,"currency_code":"HUF","in_stock":true},{"title":"3 meters (9.8') Tinned Lead","offer_id":58589153460556,"sku":"ENV-50\u0026#8211;ORP-TL","price":107847.0,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/env-50-ORP-main-04.jpg?v=1787830695"},{"product_id":"rtd3-industrial-temperature-transmitter","title":"RTD3 Industrial Temperature Transmitter","description":"\u003cp\u003eIf you have ever had to add an RTD module to a PLC, then you know firsthand just how complicated and expensive they can be. The RTD3 transmitter is designed to be a simple and cost-effective alternative to traditional RTD modules for PLCs. The RTD3 lets you connect and calibrate up to 3 temperature probes simultaneously.\u003c\/p\u003e\n\u003cp\u003eUse your PLCs 4-20mA input to get the temperature readings. The large display makes it easy to see the temperature and know which probe the reading is coming from.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTemperature (up to 3 probes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-126 °C to 1,254 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange with Atlas industrial probe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-55 °C to 220 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eScale\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e°C or °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle point @0 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported probes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAny type \u0026amp; brand PT-100 or PT-1000 RTD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMount\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35mm Din rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 − 20mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9VDC − 36VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RTD3_transmitter.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRTD3 Industrial Temperature Transmitter Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRoHS Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/csa-certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCSA Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":58589153526092,"sku":"RTD3\u0026#8211;IND","price":78430.0,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/Industrial-RTD-Transmitter-main-1.jpg?v=1787830696"},{"product_id":"ixian-conductivity-transmitter-2","title":"Industrial Conductivity Transmitter","description":"\u003cp\u003eThose of us who work with PLCs clearly understand both the power and limitations of industrial computers. Modern low voltage elections and communication protocols aren’t easily compatible with PLCs. Fortunately, the Atlas Scientific Industrial Conductivity transmitter makes it easy to get high accuracy conductivity readings on your PLC for less than half the price of comparable devices on the market today.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConductivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.07μS – 100,000μS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/– 2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 or 2 point (remotely though PLC or directly on board)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported probes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAny two lead conductivity probe (K 0.01, K 0.1, K 1.0, K 10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemp probe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePT-100 or PT-1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuto temp compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternational standard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISO 7888 compliant (determination of electrical conductivity)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMount\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35mm Din rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 − 20mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9VDC − 36VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrically isolated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/EC_transmitter.pdf\" target=\"_blank\" rel=\"noopener\"\u003eIndustrial Conductivity Transmitter Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRoHS Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/csa-certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCSA Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":58589153591628,"sku":"IND\u0026#8211;EC","price":129421.0,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/Industrial-Conductivity-Transmitter-main.jpg?v=1787830696"},{"product_id":"ixian-dissolved-oxygen-transmitter-2","title":"Industrial Dissolved Oxygen Transmitter","description":"\u003cp\u003eFor some reason buying a dissolved oxygen transmitter involves clicking the “request quote” box. I think we all know what that mean$. Atlas Scientific isn’t interested in customizing the price based on who you are. We know who you are; you’re an engineer building a machine. Like other Atlas Scientific products, this dissolved oxygen transmitter gives you a simple solution to a complex measurement. Hook it up, calibrate the probe, get the readings and move on with your life. Simple, the way it should be.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDissolved Oxygen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 mg\/L to 32.00 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/– 0.2 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 or 2 point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported probes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAny type \/ brand of galvanic D.O. probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuto temp compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSea water compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternational standard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISO 5814 compliant (determination of dissolved oxygen)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMount\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35mm Din rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 − 20mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9VDC − 36VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrically isolated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/DO_transmitter.pdf\" target=\"_blank\" rel=\"noopener\"\u003eIndustrial Dissolved Oxygen Transmitter Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRoHS Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/csa-certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCSA Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":58589153657164,"sku":"IND\u0026#8211;DO","price":105892.0,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/ixian-DO-transmitter-main.jpg?v=1787830697"},{"product_id":"ixian-orp-transmitter-copy","title":"Industrial ORP Transmitter","description":"\u003cp\u003eAnyone who has worked with PLCs knows how powerful they are. But, like anything in engineering, PLCs have their limitations. Because EZO class devices don’t integrate well with PLCs, we made the Industrial line of transmitters.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eORP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-1900.0mV − 1900.0mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/– 1mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle point (remotely though PLC or directly on board)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported probes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAny type \u0026amp; brand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuto temp compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternational standard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISO 11271 compliant (determination of redox potential)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMount\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35mm Din rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 − 20mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14VDC − 36VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrically isolated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ORP_transmitter.pdf\" target=\"_blank\" rel=\"noopener\"\u003eIndustrial ORP Transmitter Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRoHS Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/csa-certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCSA Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":58589153722700,"sku":"IND\u0026#8211;ORP","price":101970.5,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/Industrial-ORP-Transmitter-main.jpg?v=1787830697"},{"product_id":"ixian-ph-transmitter-2","title":"Industrial pH Transmitter","description":"\u003cp\u003eDesigned with PLCs in mind, the Atlas Scientific Industrial pH transmitter is a simple to use pH transmitter that gets right to the point, reading pH.\u003c\/p\u003e\n\u003cp\u003eThe DIN rail mount and wide operating voltage make it easy to install. The 4-20mA data output and display makes it easy to read. And the simple calibration protocol gets you up and running in no time.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.001 − 14.000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/– 0.002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1, 2, 3 point (remotely though PLC or directly on board)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported probes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAny type \u0026amp; brand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemp probe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePT-100 or PT-1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuto temp compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternational standard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISO 10523 compliant (determination of pH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMount\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35mm Din rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 − 20mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9VDC − 36VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrically isolated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/pH_transmitter.pdf\" target=\"_blank\" rel=\"noopener\"\u003eIndustrial pH Transmitter Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRoHS Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/csa-certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCSA Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/atlas-scientific.com\/ph-temperature-calculator\/\" target=\"_blank\" rel=\"noopener\"\u003epH Temperature Compensation Calculator\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":58589153788236,"sku":"IND\u0026#8211;pH","price":101970.5,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/Industrial-pH-Transmitter-main.jpg?v=1787830698"},{"product_id":"industrial-rtd-temperature-kit","title":"Industrial RTD Temperature Kit","description":"\u003cp\u003eIf you have ever had to add an RTD module to a PLC, then you know firsthand just how complicated and expensive they can be. The RTD3 transmitter is designed to be a simple and cost-effective alternative to traditional RTD modules for PLCs. The RTD3 lets you connect and calibrate up to 3 temperature probes simultaneously.\u003c\/p\u003e\n\u003cp\u003eUse your PLCs 4-20mA input to get the temperature readings. The large display makes it easy to see the temperature and know which probe the reading is coming from.\u003c\/p\u003e\n\u003cp\u003eThis kit comes with the RTD transmitter and x1 Industrial PT-1000 probe.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• 1x Industrial RTD Temperature Transmitter\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• 1x Industrial PT-1000 Temperature Probe\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• Probe type: Class A platinum, RTD\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• Probe Weight: 184 grams\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• Cable length: 3 Meters (10′)\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RTD3_transmitter.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRTD3 Industrial Temperature Transmitter Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Industrial-pt-1000-probe.pdf\" target=\"_blank\" rel=\"noopener\"\u003eIndustrial PT-1000 Temperature Probe Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/connecting-probes-into-a-pipe.pdf\" target=\"_blank\" rel=\"noopener\"\u003eConnecting probes into a pipe\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRoHS Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/csa-certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCSA Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":58589153821004,"sku":"KIT\u0026#8211;303","price":90194.5,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/KIT-303-main-02.jpg?v=1787830698"},{"product_id":"industrial-conductivity-kit-k-1-0-2","title":"Industrial Conductivity Kit K 1.0","description":"\u003cp\u003eAre you working with a PLC and aren’t sure what parts are right for you? Let us help you. This is the Atlas Scientific, Industrial Conductivity kit. It comes with everything you need to take high accuracy, interference-free readings with a PLC. The industrial strength conductivity probe is ready for the job, whatever it may be. This probe doesn’t care, from batch process chemical production to wastewater treatment. You can use it for anything. The DIN rail mount and wide operating voltage makes it easy to install. The 4-20mA data output and display makes it easy to read. And the simple calibration protocol gets you up and running in no time.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• 1x Industrial Conductivity Transmitter\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• 1x Industrial Conductivity Probe K 1.0\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• 2x 250ml (8oz) calibration solutions\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eK 1.0 Calibration solutions – This set includes 1 (12,880µS) and 1 (80,000µS)\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eProbe Max Pressure: 1380 kPa (200 Psi)\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eProbe Cable length: 10Ft\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eProbe Weight: 195 grams\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eInternational standard: ISO 7888 compliant (determination of electrical conductivity)\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/EC_transmitter.pdf\" target=\"_blank\" rel=\"noopener\"\u003eIndustrial Conductivity Transmitter Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/IEC_probe-K1.0.pdf\" target=\"_blank\" rel=\"noopener\"\u003eIndustrial Conductivity Probe K 1.0 Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Industrial_conductivity_k1.0.pdf\" target=\"_blank\" rel=\"noopener\"\u003eIndustrial Conductivity Calibration K 1.0 Set SDS\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/legacy-IEC_probe-K1.0.pdf\" target=\"_blank\" rel=\"noopener\"\u003eLEGACY Industrial Conductivity Probe K 1.0 Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/connecting-probes-into-a-pipe.pdf\" target=\"_blank\" rel=\"noopener\"\u003eConnecting probes into a pipe\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRoHS Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/csa-certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCSA Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"I would like a Certificate of Calibration (+75.00)","offer_id":58589153886540,"sku":"KIT–106E-CoC","price":268640.0,"currency_code":"HUF","in_stock":true},{"title":"No thank you","offer_id":58589153919308,"sku":"KIT–106E","price":239234.5,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/106e-kit-main-2.jpg?v=1787830698"},{"product_id":"industrial-dissolved-oxygen-kit-2","title":"Industrial Dissolved Oxygen Kit","description":"\u003cp\u003eAre you working with a PLC and aren’t sure what parts are right for you? Let us help you. This is the Atlas Scientific industrial Dissolved Oxygen kit. It comes with everything you need to take high accuracy, interference-free readings with a PLC. The industrial strength Dissolved Oxygen probe is ready for the job, whatever it may be. The DIN rail mount and wide operating voltage makes it easy to install. The 4-20mA data output and display makes it easy to read. And the simple calibration protocol gets you up and running in no time.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• 1x IXIAN™ Dissolved Oxygen Transmitter\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• 1x Industrial Dissolved Oxygen Probe\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• 3x 20ml Zero Dissolved Oxygen Calibration Solution Pouches\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eProbe Max Pressure: 100 PSI\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eProbe Cable length: 3 Meters (10′)\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eProbe Weight: 396 grams\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eInternational standard: ISO 5814 compliant (determination of dissolved oxygen)\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/DO_transmitter.pdf\" target=\"_blank\" rel=\"noopener\"\u003eIndustrial Dissolved Oxygen Transmitter Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Industrial-DO-probe.pdf\" target=\"_blank\" rel=\"noopener\"\u003eIndustrial Dissolved Oxygen Probe Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/connecting-probes-into-a-pipe.pdf\" target=\"_blank\" rel=\"noopener\"\u003eConnecting probes into a pipe\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRoHS Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/csa-certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCSA Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"No thank you","offer_id":58589154050380,"sku":"KIT\u0026#8211;106D","price":223548.5,"currency_code":"HUF","in_stock":true},{"title":"I would like a Certificate of Calibration (+75.00)","offer_id":58589154083148,"sku":"KIT\u0026#8211;106D-COC","price":252954.0,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/KIT-106D-main-2_088659dd-2ee5-44d7-88f0-04c2e1a360c5.jpg?v=1787830699"},{"product_id":"industrial-orp-kit-2","title":"Industrial ORP Kit","description":"\u003cp\u003eAre you working with a PLC and aren’t sure what parts are right for you? Let us help you. This is the Atlas Scientific, industrial ORP kit. It comes with everything you need to take high accuracy, interference-free readings with a PLC. The industrial strength ORP probe is ready for the job, whatever it may be. This probe doesn’t care, from batch process chemical production to wastewater treatment. You can use it for anything. The DIN rail mount and wide operating voltage makes it easy to install. The 4-20mA data output and display makes it easy to read. And the simple calibration protocol gets you up and running in no time.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• 1x Industrial ORP Transmitter\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• 1x Industrial ORP Probe\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• 2x 20ml ORP calibration solution pouches (225mV)\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• 1x 20ml pH\/ORP storage solution pouch\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eProbe Max Pressure: 689.47 kPa (100 Psi) at \u0026lt;= 75°C\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eProbe Cable length: 10Ft\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eProbe Weight: 295 grams\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eInternational standard: ISO 11271 compliant (determination of redox potential)\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ORP_transmitter.pdf\" target=\"_blank\" rel=\"noopener\"\u003eIndustrial ORP Transmitter Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/IORP_probe.pdf\" target=\"_blank\" rel=\"noopener\"\u003eIndustrial ORP Probe Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/connecting-probes-into-a-pipe.pdf\" target=\"_blank\" rel=\"noopener\"\u003eConnecting probes into a pipe\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRoHS Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/csa-certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCSA Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"I would like a Certificate of Calibration (+75.00)","offer_id":58589154148684,"sku":"KIT\u0026#8211;103O","price":225503.5,"currency_code":"HUF","in_stock":true},{"title":"No thank you","offer_id":58589154181452,"sku":"KIT\u0026#8211;103O","price":196086.5,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/KIT-103O-main-2_4d56d92f-d21f-4351-8466-d01926bdcba0.jpg?v=1787830699"},{"product_id":"gen-3-industrial-gold-orp-probe","title":"Industrial Gold ORP Probe","description":"\u003cp\u003eGold ORP probes work very well in saltwater pools. This is because gold has catalytic properties different from traditional platinum ORP probes and exhibits different sensitivities to certain redox reactions. It is also reported that gold ORP probes work better in highly reducing water, such as “produced water” from oil wells, which typically has a negate (or reducing) ORP of -200mv or more.\u003c\/p\u003e\n\u003cp\u003eGold ORP probes are slightly more expensive than platinum ORP probes because binding gold to glass is more difficult and requires more energy.\u003c\/p\u003e\n\u003cp\u003eEach probe comes with its own unique 12-digit serial number for tracking and traceability.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eUnique 12-digit serial number\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eORP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-2000mV – 2000mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/– 1mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% in 1s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature range °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 − 99 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensing element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70m (230′)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSMA or Tinned leads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 meters (9.8′)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal temperature sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTime before recalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLife expectancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~4 Years +\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/IORP_probe_gold.pdf\" target=\"_blank\" rel=\"noopener\"\u003eIndustrial Gold ORP Probe Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/connecting-probes-into-a-pipe.pdf\" target=\"_blank\" rel=\"noopener\"\u003eConnecting probes into a pipe\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRoHS Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ELR-No-10-2011.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEuropean legislation Regulation (EU) No 10\/2011\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ELR-No-1935-2004.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEuropean legislation Regulation (EU) No 1935\/2004\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/csa-certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCSA Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ENV-50-ORP.zip\" target=\"_blank\" rel=\"noopener\"\u003eENV-50-ORP 3D model (*step)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"3 meters (9.8') SMA","offer_id":58589236560204,"sku":"ENV-50-ORP-G-SMA-1","price":119611.5,"currency_code":"HUF","in_stock":true},{"title":"3 meters (9.8') Tinned Lead","offer_id":58589236592972,"sku":"ENV-50-ORP-G-TL-1","price":117656.5,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/env-50-ORP-g-main-2.jpg?v=1787831109"},{"product_id":"industrial-tri-clamp-probe-pipe-fitting-2","title":"Industrial Tri-Clamp Probe Pipe Fitting","description":"\u003cp\u003eThe Industrial Tri-Clamp pipe fitting is compatible with most of our Industrial Probes; the Tri-Clamp pipe fitting connects to any 1.5” (50.5 cm) standard sanitary pipe.\u003c\/p\u003e\n\u003cp\u003eCompatible with: Industrial pH Probe Industrial ORP Probe Industrial Dissolved Oxygen Probe Industrial PT-1000 Probe Industrial pH\/ORP\/Temp Probe\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• 1x stainless steel 1.5″ Tri Clamp to NPT Port\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• Food Safe\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• Max Pressure: 689.47 kPa (100 psi) 6.89 bar\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• Max temperature: 100 ˚C (212˚F) 373.15 ˚K\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/connecting-probes-into-a-pipe.pdf\" target=\"_blank\" rel=\"noopener\"\u003eConnecting probes into a pipe\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":58589538582860,"sku":"I-tri\u0026#8211;clamp","price":12937.5,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/industrial-tri-clamp-pipe-fitting-main_b259ffd2-0393-4830-b2f8-d0ef0fbc024d.jpg?v=1787831705"},{"product_id":"industrial-conductivity-probe-k-0-1-2","title":"Industrial Conductivity Probe K 0.1","description":"\u003cp\u003eThe Atlas Scientific Industrial Conductivity Probe K 0.1 is a rugged sensor engineered for precise, low-range conductivity measurements in demanding environments. Designed for versatility, it performs reliably across applications ranging from industrial chemical processing to water quality monitoring. Featuring a durable 3\/4″ NPT threaded body for easy installation and an integrated PT-1000 temperature sensor for accurate compensation, the probe delivers fast, stable readings with minimal maintenance. Its electrolyte-free design eliminates depletion concerns, allowing for long service life and calibration intervals measured in years rather than months.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConductivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.07 − 50,000 μS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/ – 2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90% in 1s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature range °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 − 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e141m (463 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSMA or Tinned leads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 meters (10′)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal temperature sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes (PT-1000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTime before recalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLife expectancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/IEC_probe-K0.1.pdf\" target=\"_blank\" rel=\"noopener\"\u003eIndustrial Conductivity Probe K 0.1 Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/legacy-IEC_probe-K0.1.pdf\" target=\"_blank\" rel=\"noopener\"\u003eLEGACY Industrial Conductivity Probe K 0.1 Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/connecting-probes-into-a-pipe.pdf\" target=\"_blank\" rel=\"noopener\"\u003eConnecting probes into a pipe\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRoHS Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/csa-certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCSA Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"Tinned Leads","offer_id":58589538615628,"sku":"ENV-50\u0026#8211;EC-K0.1","price":107847.0,"currency_code":"HUF","in_stock":true},{"title":"SMA","offer_id":58589538648396,"sku":"ENV-50\u0026#8211;EC-K0.1-SMA","price":111768.5,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/iec-probe-k01-main_54a812ec-2767-4ac4-821d-7350db55a906.jpg?v=1787831705"},{"product_id":"industrial-conductivity-kit-k-0-1-2","title":"Industrial Conductivity Kit K 0.1","description":"\u003cp\u003eAre you working with a PLC and aren’t sure what parts are right for you? Let us help you. This is the Atlas Scientific, Industrial Conductivity kit. It comes with everything you need to take high accuracy, interference-free readings with a PLC. The industrial strength conductivity probe is ready for the job, whatever it may be. This probe doesn’t care, from batch process chemical production to wastewater treatment. You can use it for anything. The DIN rail mount and wide operating voltage makes it easy to install. The 4-20mA data output and display makes it easy to read. And the simple calibration protocol gets you up and running in no time.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• 1x Industrial Conductivity Transmitter\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• 1x Industrial Conductivity Probe K 0.1\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• 2x 250ml (8oz) calibration solutions\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eK 0.1 Low – This set includes 1 (84µS) and 1 (1,413µS)\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eK 0.1 Normal – This set includes 1 (1,413µS) and 1 (12,880µS)\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eProbe Max Pressure: 1380 kPa (200 Psi)\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eProbe Cable length: 10Ft\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eProbe Weight: 195 grams\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eInternational standard: ISO 7888 compliant (determination of electrical conductivity)\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/EC_transmitter.pdf\" target=\"_blank\" rel=\"noopener\"\u003eIndustrial Conductivity Transmitter Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/IEC_probe-K0.1.pdf\" target=\"_blank\" rel=\"noopener\"\u003eIndustrial Conductivity Probe K 0.1 Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Conductivity-k0.1-SDS.pdf\" target=\"_blank\" rel=\"noopener\"\u003eIndustrial Conductivity Calibration K 0.1 Set SDS\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/legacy-IEC_probe-K0.1.pdf\" target=\"_blank\" rel=\"noopener\"\u003eLEGACY Industrial Conductivity Probe K 0.1 Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/connecting-probes-into-a-pipe.pdf\" target=\"_blank\" rel=\"noopener\"\u003eConnecting probes into a pipe\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRoHS Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/csa-certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCSA Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"Normal Mode: 0 – 25,000µS \/ No thank you","offer_id":58598479102284,"sku":"KIT\u0026#8211;107E","price":231391.5,"currency_code":"HUF","in_stock":true},{"title":"Normal Mode: 0 – 25,000µS \/ I would like a Certificate of Calibration (+75.00)","offer_id":58598479135052,"sku":"KIT\u0026#8211;107E-CoC","price":260797.0,"currency_code":"HUF","in_stock":true},{"title":"Low Mode: 0.07 – 2,000µS \/ No thank you","offer_id":58598479167820,"sku":"KIT\u0026#8211;107E-L","price":231391.5,"currency_code":"HUF","in_stock":true},{"title":"Low Mode: 0.07 – 2,000µS \/ I would like a Certificate of Calibration (+75.00)","offer_id":58598479200588,"sku":"KIT\u0026#8211;107E-L-CoC","price":260797.0,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/107e-kit-main02.jpg?v=1787894152"}],"url":"https:\/\/waterscopeiot.com\/collections\/ipari-muszerek.oembed","provider":"WaterScope IoT store","version":"1.0","type":"link"}