{"title":"Szenzorok","description":"\u003cp\u003eAtlas Scientific mérőszondák és beágyazott szenzorok: pH, ORP, oldott oxigén, vezetőképesség, hőmérséklet, CO2, szín, páratartalom, nyomás.\u003c\/p\u003e","products":[{"product_id":"industrial-ph-probe","title":"Industrial pH Probe – with Temp","description":"\u003cp\u003eDesigned for industrial process control, the Atlas Scientific industrial pH probe has all the capabilities of our lab-grade pH probe and more!\u003c\/p\u003e\n\u003cp\u003eThe probe’s body is made of Delrin, a strong and highly chemical-resistant thermoplastic. A Teflon junction connects the pH probe to the outside world. The Teflon junction makes this probe ideal for wine production because tartrate crystals can not form on Teflon. The Teflon junction also makes this probe well-suited for highly corrosive environments. Unlike traditional pH probes that have a glass bulb at its tip, this probe has a flat sensing area. That means that you never have to worry about the glass breaking off into your liquid; And we didn’t even mention the 3\/4″ NPT threaded body or internal temperature sensor!\u003c\/p\u003e\n\u003cp\u003eEach probe comes with its own unique 12-digit serial number for tracking and traceability.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eDouble junction\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003esilver \/ silver chloride\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eUnique 12-digit serial number\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 − 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% in 1s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature range °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 − 99 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70m (230′)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSMA or Tinned leads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 meters (9.8′)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal temperature sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes (PT-1000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTime before recalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLife expectancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~4 Years +\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/IpH_probe_with_temp.pdf\" target=\"_blank\" rel=\"noopener\"\u003epH Industrial Probe with Temp Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/connecting-probes-into-a-pipe.pdf\" target=\"_blank\" rel=\"noopener\"\u003eConnecting probes into a pipe\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRoHS Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/csa-certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCSA Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ELR-No-10-2011.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEuropean legislation Regulation (EU) No 10\/2011\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ELR-No-1935-2004.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEuropean legislation Regulation (EU) No 1935\/2004\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/atlas-scientific.com\/ph-temperature-calculator\/\" target=\"_blank\" rel=\"noopener\"\u003epH Temperature Compensation Calculator\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Gen3_Industrial-pH-temp.zip\" target=\"_blank\" rel=\"noopener\"\u003eENV-50-pH 3D model (*step)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"Tinned Leads","offer_id":58589119185228,"sku":"ENV-50-pH","price":125499.5,"currency_code":"HUF","in_stock":true},{"title":"SMA","offer_id":58589119217996,"sku":"ENV-50-pH-SMA","price":129421.0,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/ENV-50-pH-main-3.jpg?v=1787830385"},{"product_id":"a-10-analog-pressure-sensor","title":"A-10 Analog Pressure Sensor","description":"\u003cp\u003eThe Atlas Scientific A-10 Analog Pressure Sensor enables accurate pressure monitoring in diverse applications, offering a reliable solution for obtaining real-time analog pressure data with precision and consistency.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePressure (PSIG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 – 10 psig (0 – 68.94kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1mv (.0025 psi \/0.017 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;± 0.1 psi (0.689 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTinned leads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalog voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 VDC – 4.5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDurability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/A-10_analog_pressure_sensor.pdf\" target=\"_blank\" rel=\"noopener\"\u003eA-10 Analog Pressure Sensor Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRoHS Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/csa-certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCSA Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Arduino-Uno-A-10-pressure-sample-code.pdf\" target=\"_blank\" rel=\"noopener\"\u003eArduino Uno Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Arduino-Mega-A-10-pressure-sample-code.pdf\" target=\"_blank\" rel=\"noopener\"\u003eArduino Mega Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/A-10-APS-1.zip\" target=\"_blank\" rel=\"noopener\"\u003eA10-APS 3D model (*step)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":58589146087756,"sku":"A10-APS","price":70587.0,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/A-10-main-2.jpg?v=1787830637"},{"product_id":"a-100-analog-pressure-sensor","title":"A-100 Analog Pressure Sensor","description":"\u003cp\u003eThe Atlas Scientific A-100 Analog Pressure Sensor provides high-precision pressure measurements, making it a valuable component for applications requiring accurate analog pressure data, ensuring reliability and performance in industrial and scientific settings.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePressure (PSIG)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 – 100 psig ( 0 – 689 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1mv (.025 psi \/0.17 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;± 1 psi (6.89 kPa)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTinned leads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnalog voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 VDC – 4.5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDurability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/A-100_analog_pressure_sensor.pdf\" target=\"_blank\" rel=\"noopener\"\u003eA-100 Analog Pressure Sensor Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRoHS Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/csa-certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCSA Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Arduino-Uno-A-100-pressure-sample-code.pdf\" target=\"_blank\" rel=\"noopener\"\u003eArduino Uno Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Arduino-Mega-A-100-pressure-sample-code.pdf\" target=\"_blank\" rel=\"noopener\"\u003eArduino Mega Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/A-100-APS.zip\" target=\"_blank\" rel=\"noopener\"\u003eA100-APS 3D model (*step)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":58589146546508,"sku":"A100-APS","price":70587.0,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/A-100-main-2.jpg?v=1787830637"},{"product_id":"orp-storage-solution","title":"ORP Probe Storage Solution","description":"\u003cp\u003eAtlas Scientific pH\/ORP storage solution is about as exciting as it gets!\u003c\/p\u003e\n\u003cp\u003eThis 3 molar KCl solution is packed with Kathon GC preservative and topped off with a dash of potassium phthalate. If you are looking to enter the exciting world of long term probe storage, look no further than Atlas Scientific pH\/ORP storage solution.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• ORP Probe Storage Solution\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• 125ml (4oz)\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• 2 year shelf life at room temperature\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ORP-Storage-SDS.pdf\" target=\"_blank\" rel=\"noopener\"\u003eORP Storage Solution SDS\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":58589146743116,"sku":"Chem-ORP-S","price":5485.5,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/ORP-Storage-solution-00.jpg?v=1787830639"},{"product_id":"mini-ph-probe","title":"Mini Lab Grade pH Probe","description":"\u003cp\u003eIf space is an issue, the Atlas Scientific mini lab grade pH probe might be for you. This probe offers the same performance as our lab grade pH probe but in a smaller package. We have seen that a lot of engineers are using these probes inside small bench-top machines and underwater environmental monitoring applications.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eSilver \/ silver chloride\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 − 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/– 0.002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% in 1s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature range °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 − 99 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e78m (254 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMale SMA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 meter (3.2′)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal temperature sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTime before recalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLife expectancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~2 Years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Mini_pH_probe.pdf\" target=\"_blank\" rel=\"noopener\"\u003eMini Lab Grade pH Probe Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ph_soil.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHow to measure the pH of soil\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/how-to-properly-cut-probe-cables.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHow to properly cut your probe cable\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/connecting-probes-into-a-pipe.pdf\" target=\"_blank\" rel=\"noopener\"\u003eConnecting probes into a pipe\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRoHS Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/csa-certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCSA Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ELR-No-10-2011.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEuropean legislation Regulation (EU) No 10\/2011\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ELR-No-1935-2004.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEuropean legislation Regulation (EU) No 1935\/2004\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/atlas-scientific.com\/ph-temperature-calculator\/\" target=\"_blank\" rel=\"noopener\"\u003epH Temperature Compensation Calculator\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ENV-20-pH.zip\" target=\"_blank\" rel=\"noopener\"\u003eENV-20-pH 3D model (*step)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":58589147136332,"sku":"ENV-20-pH","price":39215.0,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/env-20-pH-main.jpg?v=1787830641"},{"product_id":"env-co2-environmental-grade-co2-sensor-copy","title":"ENV-CO2™ Environmental Grade CO2 Sensor – Stainless Steel Body","description":"\u003cp\u003eThe ENV-CO2™ Environmental Grade CO₂ Sensor delivers precise and dependable carbon dioxide measurements across a wide range of applications. Factory calibrated and ready for immediate deployment, it accurately measures concentrations from 400 to 5,000 ppm. The rugged housing is constructed from 316 stainless steel, providing excellent durability and corrosion resistance in demanding environments. Designed for long-term reliability, the sensor features low power consumption and seamless integration via UART or I²C communication. Whether used for indoor air quality monitoring, greenhouse management, or research environments, the ENV-CO2-S™ provides consistent, real-time data you can rely on.\u003c\/p\u003e\n\u003cp\u003eThe ENV-CO2-S™ comes with: One embedded carbon dioxide sensor with stainless steel body, one data cable with 5 pin male header, and one Locknut \u0026amp; O-ring.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGaseous CO2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 − 5,000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSelf calibration or user calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70.0 – 120.0 kPa (0.7 – 1.2 atm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReading time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 reading per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- (40 ppm + 5% of reading)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eT63: 60 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBody material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e316 Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 lead data cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUART \u0026amp; I2C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDefault I2C address\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e113 (0x71)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eASCII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.3V − 5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLife expectancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~8 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ENV_CO2_S_Datasheet.pdf\" target=\"_blank\" rel=\"noopener\"\u003eENV-CO2™ Stainless Steel Body Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/0022012057_CRIMP_HOUSINGS.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFemale connector information\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRoHS Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/csa-certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCSA Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/AtlasDesktop.zip\" target=\"_blank\" rel=\"noopener\"\u003eFREE Software - AtlasDesktop Monitoring Software\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Atlasdesktop-user-guide.pdf\" target=\"_blank\" rel=\"noopener\"\u003eAtlasDesktop Monitoring Software Users Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Arduino-Uno-CO2E-sample-code.pdf\" target=\"_blank\" rel=\"noopener\"\u003eArduino Uno Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Arduino-Mega-Giga-CO2E-Sample-Code.pdf\" target=\"_blank\" rel=\"noopener\"\u003eArduino Mega \/ Giga Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Ardunio-I2C-CO2E-sample-code.pdf\" target=\"_blank\" rel=\"noopener\"\u003eArduino I2C Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/pi_sample_code.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRaspberry Pi Sample Code (I2C)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/github.com\/Atlas-Scientific\/Ezo_uart_lib\" target=\"_blank\" rel=\"noopener\"\u003eEZO UART Library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/github.com\/Atlas-Scientific\/Ezo_I2c_lib\" target=\"_blank\" rel=\"noopener\"\u003eEZO I2C Library\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"I would like a Certificate of Calibration (+55.00)","offer_id":58589151691084,"sku":"ENV-CO2-S-CoC","price":100004.0,"currency_code":"HUF","in_stock":true},{"title":"No thank you","offer_id":58589151723852,"sku":"ENV-CO2-S","price":78430.0,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/ENV-CO2-S-main.jpg?v=1787830682"},{"product_id":"ezo-o2-embedded-oxygen-sensor-no-housing","title":"EZO-O2™ Embedded Oxygen Sensor – No Housing","description":"\u003cp\u003eThe Atlas Scientific gaseous oxygen sensor, offers precision measurement of oxygen levels from 0 to 420 ppt, ideal for both environmental and industrial applications. Pre-calibrated for immediate use, its durable design is perfect for demanding settings, ensuring reliable performance right out of the box.\u003c\/p\u003e\n\u003cp\u003eThe EZO-O2-NH™ comes with: One embedded oxygen sensor without any housing, one data cable with 5 pin male header, and one Locknut \u0026amp; O-ring.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGaseous O2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 – 42% (2x atmospheric O2 levels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFactory calibrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAtmosphere only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 reading per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.01% (0.2 PPT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBody material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo Housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 lead data cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUART \u0026amp; I2C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDefault I2C Address\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e108 (0x6c)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eASCII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.3V – 5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLife expectancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~3.5 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/EZO_O2_P_datasheet.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEZO-O2™ Plastic Body Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/0022012057_CRIMP_HOUSINGS.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFemale connector information\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRoHS Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/csa-certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCSA Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/AtlasDesktop.zip\" target=\"_blank\" rel=\"noopener\"\u003eFREE Software - AtlasDesktop Monitoring Software\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Atlasdesktop-user-guide.pdf\" target=\"_blank\" rel=\"noopener\"\u003eAtlasDesktop Monitoring Software Users Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Arduino-Uno-O2-sample-code.pdf\" target=\"_blank\" rel=\"noopener\"\u003eArduino Uno Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Arduino-Mega-Giga-O2-Sample-Code.pdf\" target=\"_blank\" rel=\"noopener\"\u003eArduino Mega \/ Giga Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Ardunio-I2C-O2-sample-code.pdf\" target=\"_blank\" rel=\"noopener\"\u003eArduino I2C Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/pi_sample_code.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRaspberry Pi Sample Code (I2C)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/github.com\/Atlas-Scientific\/Ezo_uart_lib\" target=\"_blank\" rel=\"noopener\"\u003eEZO UART Library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/github.com\/Atlas-Scientific\/Ezo_I2c_lib\" target=\"_blank\" rel=\"noopener\"\u003eEZO I2C Library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/EZO-O2.zip\" target=\"_blank\" rel=\"noopener\"\u003eEZO-O2™ 3D model (*step)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":58589151756620,"sku":"EZO-o2-NH","price":39215.0,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/o2-no-housing-main.jpg?v=1787830683"},{"product_id":"micro-ph-reference-replacement","title":"Micro Reference Probe Replacement","description":"\u003cp\u003eThis probe is designed as a replacement for the Micro Reference Probe. A Micro pH probe is required to obtain readings with this probe.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• 1 Micro Reference Probe\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Micro-pH-probe.pdf\" target=\"_blank\" rel=\"noopener\"\u003eMicro pH Probe Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/pH-flow-cell-spec-sheet.pdf\" target=\"_blank\" rel=\"noopener\"\u003epH Flow Cell Specsheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRoHS Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/csa-certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCSA Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ELR-No-10-2011.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEuropean legislation Regulation (EU) No 10\/2011\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ELR-No-1935-2004.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEuropean legislation Regulation (EU) No 1935\/2004\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/atlas-scientific.com\/ph-temperature-calculator\/\" target=\"_blank\" rel=\"noopener\"\u003epH Temperature Compensation Calculator\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":58589151789388,"sku":"ENV-10-ref","price":47058.0,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/env-10-ph-ref-main.jpg?v=1787830684"},{"product_id":"micro-ph-probe-replacement","title":"Micro pH Probe Replacement","description":"\u003cp\u003eThis probe is designed as a replacement for the Micro pH Probe. A Micro Reference Probe is required to obtain readings with this probe.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• 1 Micro pH Probe\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Micro-pH-probe.pdf\" target=\"_blank\" rel=\"noopener\"\u003eMicro pH Probe Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/pH-flow-cell-spec-sheet.pdf\" target=\"_blank\" rel=\"noopener\"\u003epH Flow Cell Specsheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRoHS Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/csa-certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCSA Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ELR-No-10-2011.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEuropean legislation Regulation (EU) No 10\/2011\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ELR-No-1935-2004.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEuropean legislation Regulation (EU) No 1935\/2004\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/atlas-scientific.com\/ph-temperature-calculator\/\" target=\"_blank\" rel=\"noopener\"\u003epH Temperature Compensation Calculator\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":58589151822156,"sku":"ENV-10-pH-R","price":47058.0,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/env-10-ph-r-main.jpg?v=1787830684"},{"product_id":"ph-flow-cell","title":"Micro pH Flow Cell","description":"\u003cp\u003eDesigned specifically around our line of micro pH probes; The Atlas Scientific Micro pH flow cell makes it easy to get stable, repeatable pH readings in a flowing stream without needing a beaker or an open sample cup. This flow cell minimizes sample volume and reduces lag time, so you can track changes faster while keeping the sensor protected and properly positioned. The Micro pH flow cell offers a clean, compact solution for inline and recirculating systems where space is tight and consistency matters.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• 1x Micro Flow Cell\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• 1x Syringe\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• 2x 1 foot of tubing\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• 3x 20ml Atlas Scientific calibration solutions pouches (pH 4, 7 and 10)\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/pH-flow-cell-spec-sheet.pdf\" target=\"_blank\" rel=\"noopener\"\u003eMicro pH Flow Cell Specsheet\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":58589152018764,"sku":"pH-MFC","price":29405.5,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/ph-flow-cell-main3.jpg?v=1787830685"},{"product_id":"env-co2-environmental-grade-co2-sensor","title":"ENV-CO2™ Environmental Grade CO2 Sensor – Plastic Body","description":"\u003cp\u003eThe ENV-CO2-P™ Environmental Grade CO₂ Sensor delivers accurate, dependable CO₂ measurements in virtually any setting. Factory calibrated and ready to use out of the box, it precisely measures concentrations from 400 to 5,000 ppm. Housed in durable black resin, it’s designed for long-term performance and features low power consumption with seamless integration via UART or I²C. Whether you’re monitoring indoor air quality, optimizing greenhouse conditions, or conducting research, the ENV-CO2-P™ provides reliable, real-time data you can count on.\u003c\/p\u003e\n\u003cp\u003eThe ENV-CO2-P™ Environmental Grade CO2 Sensor comes with: One embedded carbon dioxide sensor with plastic body, one data cable with 5 pin male header, and one Locknut \u0026amp; O-ring\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGaseous CO2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400 − 5,000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSelf calibration or user calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70.0 – 120.0 kPa (0.7 – 1.2 atm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReading time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 reading per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- (40 ppm + 5% of reading)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eT63: 60 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBody material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBlack – Photosensitive Resin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 lead data cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUART \u0026amp; I2C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDefault I2C address\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e113 (0x71)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eASCII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.3V − 5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLife expectancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~8 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ENV_CO2_P_Datasheet.pdf\" target=\"_blank\" rel=\"noopener\"\u003eENV-CO2™ Plastic Body Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/0022012057_CRIMP_HOUSINGS.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFemale connector information\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRoHS Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/csa-certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCSA Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/AtlasDesktop.zip\" target=\"_blank\" rel=\"noopener\"\u003eFREE Software - AtlasDesktop Monitoring Software\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Atlasdesktop-user-guide.pdf\" target=\"_blank\" rel=\"noopener\"\u003eAtlasDesktop Monitoring Software Users Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Arduino-Uno-CO2E-sample-code.pdf\" target=\"_blank\" rel=\"noopener\"\u003eArduino Uno Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Arduino-Mega-Giga-CO2E-Sample-Code.pdf\" target=\"_blank\" rel=\"noopener\"\u003eArduino Mega \/ Giga Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Ardunio-I2C-CO2E-sample-code.pdf\" target=\"_blank\" rel=\"noopener\"\u003eArduino I2C Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/pi_sample_code.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRaspberry Pi Sample Code (I2C)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/github.com\/Atlas-Scientific\/Ezo_uart_lib\" target=\"_blank\" rel=\"noopener\"\u003eEZO UART Library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/github.com\/Atlas-Scientific\/Ezo_I2c_lib\" target=\"_blank\" rel=\"noopener\"\u003eEZO I2C Library\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"I would like a Certificate of Calibration (+55.00)","offer_id":58589152051532,"sku":"ENV-CO2-P-CoC","price":80396.5,"currency_code":"HUF","in_stock":true},{"title":"No thank you","offer_id":58589152084300,"sku":"ENV-CO2-P","price":58822.5,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/ENV-CO2-main-2.jpg?v=1787830685"},{"product_id":"lab-grade-dissolved-oxygen-maintenance-kit","title":"Lab Grade Dissolved Oxygen Maintenance Kit","description":"\u003cp\u003eThe lab grade dissolved oxygen maintenance kit restores old or dried-out lab grade dissolved oxygen probes, bringing them back to working condition.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• 2x Lab Grade Dissolved Oxygen probe replacement membranes\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• 2x Zero Dissolved Oxygen Calibration Solution pouches\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• 1x Bottle of replacement electrolyte solution\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• 1x Bottle of corrosion remover\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• 1x Syringe\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/kit-108d-instructions.pdf\" target=\"_blank\" rel=\"noopener\"\u003eLab Grade Dissolved Oxygen Maintenance Kit Instructions\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/dissolved-oxygen-corrosion-remover-sds.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDissolved Oxygen Corrosion Revmover SDS\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Dissolved-Oxygen-Electrolyte-Solution-SDS.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDissolved Oxygen Electrolyte Solution SDS\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":58589152280908,"sku":"Kit-108D","price":31372.0,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/kit-108d-main2.jpg?v=1787830687"},{"product_id":"industrial-dissolved-oxygen-kit","title":"Industrial Dissolved Oxygen Kit","description":"\u003cp\u003eAre you working with a PLC and aren’t sure what parts are right for you? Let us help you. This is the Atlas Scientific industrial Dissolved Oxygen kit. It comes with everything you need to take high accuracy, interference-free readings with a PLC. The industrial strength Dissolved Oxygen probe is ready for the job, whatever it may be. The DIN rail mount and wide operating voltage makes it easy to install. The 4-20mA data output and display makes it easy to read. And the simple calibration protocol gets you up and running in no time.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• 1x Industrial Dissolved Oxygen Transmitter\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• 1x Industrial Dissolved Oxygen Probe\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• 3x 20ml Zero Dissolved Oxygen Calibration Solution Pouches\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eProbe Max Pressure: 100 PSI\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eProbe Cable length: 3 Meters (10′)\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eProbe Weight: 396 grams\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eInternational standard: ISO 5814 compliant (determination of dissolved oxygen)\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/DO_transmitter.pdf\" target=\"_blank\" rel=\"noopener\"\u003eIndustrial Dissolved Oxygen Transmitter Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Industrial-DO-probe.pdf\" target=\"_blank\" rel=\"noopener\"\u003eIndustrial Dissolved Oxygen Probe Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/connecting-probes-into-a-pipe.pdf\" target=\"_blank\" rel=\"noopener\"\u003eConnecting probes into a pipe\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRoHS Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/csa-certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCSA Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/atlas-scientific.com\/dissolved-oxygen-calculator\" target=\"_blank\" rel=\"noopener\"\u003eDissolved Oxygen Calculator\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"I would like a Certificate of Calibration (+75.00)","offer_id":58589153984844,"sku":"KIT-106D-CoC","price":252954.0,"currency_code":"HUF","in_stock":true},{"title":"No thank you","offer_id":58589154017612,"sku":"KIT-106D","price":223548.5,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/KIT-106D-main-2.jpg?v=1787830699"},{"product_id":"ixian-dissolved-oxygen-transmitter","title":"Industrial Dissolved Oxygen Transmitter","description":"\u003cp\u003eFor some reason buying a dissolved oxygen transmitter involves clicking the “request quote” box. I think we all know what that mean$. Atlas Scientific isn’t interested in customizing the price based on who you are. We know who you are; you’re an engineer building a machine. Like other Atlas Scientific products, this dissolved oxygen transmitter gives you a simple solution to a complex measurement. Hook it up, calibrate the probe, get the readings and move on with your life. Simple, the way it should be.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDissolved Oxygen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 mg\/L to 32.00 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/– 0.2 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 or 2 point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported probes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAny type \/ brand of galvanic D.O. probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuto temp compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSea water compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternational standard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISO 5814 compliant (determination of dissolved oxygen)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMount\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35mm Din rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 − 20mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9VDC − 36VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrically isolated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/DO_transmitter.pdf\" target=\"_blank\" rel=\"noopener\"\u003eIndustrial Dissolved Oxygen Transmitter Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRoHS Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/csa-certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCSA Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/atlas-scientific.com\/dissolved-oxygen-calculator\" target=\"_blank\" rel=\"noopener\"\u003eDissolved Oxygen Calculator\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":58589154115916,"sku":"IND-DO","price":105892.0,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/ixian-DO-transmitter-main_a6bac54c-b737-4e69-b290-b4ee435a8808.jpg?v=1787830699"},{"product_id":"industrial-dissolved-oxygen-probe","title":"Industrial Dissolved Oxygen Probe","description":"\u003cp\u003eWhen you need long term readings from a probe that’s almost impossible to break, the Atlas Scientific Industrial Dissolved Oxygen probe is what you need. The probe holds a lot of electrolyte so it will last for a long time before needing reconditioning. The built-in PT-1000 temperature sensor and threaded body reduces the need for excess parts and makes it easy to install in a pipe.\u003c\/p\u003e\n\u003cp\u003eEach probe comes with its own unique 12-digit serial number for tracking and traceability.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eUnique 12-digit serial number\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDissolved Oxygen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 − 100 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/– 0.05 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~0.1 mg\/L\/per sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature range °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 − 99 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e212m (694 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSMA or Tinned leads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 Meters (10′)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal temperature sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes (PT-1000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTime before recalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLife expectancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~4 Years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaintenance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~18 Months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Industrial-DO-probe.pdf\" target=\"_blank\" rel=\"noopener\"\u003eIndustrial Dissolved Oxygen Probe Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/connecting-probes-into-a-pipe.pdf\" target=\"_blank\" rel=\"noopener\"\u003eConnecting probes into a pipe\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRoHS Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/csa-certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCSA Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ELR-No-10-2011.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEuropean legislation Regulation (EU) No 10\/2011\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ELR-No-1935-2004.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEuropean legislation Regulation (EU) No 1935\/2004\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Gen3_Industrial-DO.zip\" target=\"_blank\" rel=\"noopener\"\u003eENV-50-DO 3D model (*step)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"Tinned Leads","offer_id":58589154214220,"sku":"ENV-50-DO","price":129421.0,"currency_code":"HUF","in_stock":true},{"title":"SMA","offer_id":58589154246988,"sku":"ENV-50-DO-SMA","price":133342.5,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/env-50-do-main-06_60ed411d-8fff-4634-a193-daf061a5c315.jpg?v=1787830700"},{"product_id":"dissolved-oxygen-mini-lab-grade-membrane-replacement-kit-copy","title":"Mini Lab Grade Dissolved Oxygen Membrane Replacement Kit","description":"\u003cp\u003eThis product is used to replace the PTFE sensing membrane for the Mini Lab Grade Dissolved Oxygen probes.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• 2x Mini Lab Grade Dissolved Oxygen probe replacement membranes\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eThis product is used to replace the PTFE sensing membrane for the Mini Lab Grade Dissolved Oxygen probes.\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":58589154312524,"sku":"DO-MEM-RM","price":22747.0,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/Mini-DO-lab-grade-probe-membrane-replacement-main.jpg?v=1787830700"},{"product_id":"industrial-conductivity-probe-k-0-1","title":"Industrial Conductivity Probe K 0.1","description":"\u003cp\u003eThe Atlas Scientific Industrial Conductivity Probe K 0.1 is a rugged sensor engineered for precise, low-range conductivity measurements in demanding environments. Designed for versatility, it performs reliably across applications ranging from industrial chemical processing to water quality monitoring. Featuring a durable 3\/4″ NPT threaded body for easy installation and an integrated PT-1000 temperature sensor for accurate compensation, the probe delivers fast, stable readings with minimal maintenance. Its electrolyte-free design eliminates depletion concerns, allowing for long service life and calibration intervals measured in years rather than months.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConductivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.07 − 50,000 μS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/ – 2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90% in 1s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature range °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 − 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e141m (463 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSMA or Tinned leads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 meters (10′)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal temperature sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes (PT-1000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTime before recalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLife expectancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/IEC_probe-K0.1.pdf\" target=\"_blank\" rel=\"noopener\"\u003eIndustrial Conductivity Probe K 0.1 Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/legacy-IEC_probe-K0.1.pdf\" target=\"_blank\" rel=\"noopener\"\u003eLEGACY Industrial Conductivity Probe K 0.1 Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/connecting-probes-into-a-pipe.pdf\" target=\"_blank\" rel=\"noopener\"\u003eConnecting probes into a pipe\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRoHS Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/csa-certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCSA Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ELR-No-10-2011.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEuropean legislation Regulation (EU) No 10\/2011\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ELR-No-1935-2004.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEuropean legislation Regulation (EU) No 1935\/2004\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"SMA","offer_id":58589154345292,"sku":"ENV-50-EC-K0.1-SMA","price":111768.5,"currency_code":"HUF","in_stock":true},{"title":"Tinned Leads","offer_id":58589154378060,"sku":"ENV-50-EC-K0.1","price":107847.0,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/iec-probe-k01-main.jpg?v=1787830701"},{"product_id":"ph-probe","title":"Lab Grade pH Probe","description":"\u003cp\u003eThe Atlas Scientific Lab Grade pH Probe delivers exceptional accuracy for precise laboratory measurements. The internal double junction lets you read the pH of protein-rich solutions without damaging the probe. The green Vanadium III tip is a hydrogen amplifier, reducing noise and increasing reading stability. A Tyvek™ junction connects the pH probe to the outside world. Because Tyvek™ resists water flow, the internal electrolyte is held in the probe longer, leading to less frequent recalibrations.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eDouble junction\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003esilver \/ silver chloride\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 − 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% in 1s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature range °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 − 99 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70m (230 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMale SMA \/ Male BNC (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal temperature sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTime before recalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLife expectancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~2.5 Years +\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/pH_probe.pdf\" target=\"_blank\" rel=\"noopener\"\u003eLab Grade pH Probe Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ph_soil.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHow to measure the pH of soil\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/how-to-properly-cut-probe-cables.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHow to properly cut your probe cable\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/connecting-probes-into-a-pipe.pdf\" target=\"_blank\" rel=\"noopener\"\u003eConnecting probes into a pipe\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRoHS Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/csa-certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCSA Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ELR-No-10-2011.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEuropean legislation Regulation (EU) No 10\/2011\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ELR-No-1935-2004.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEuropean legislation Regulation (EU) No 1935\/2004\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/atlas-scientific.com\/ph-temperature-calculator\/\" target=\"_blank\" rel=\"noopener\"\u003epH Temperature Compensation Calculator\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ENV-40-pH.zip\" target=\"_blank\" rel=\"noopener\"\u003eENV-40-pH 3D model (*step)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"Do not include","offer_id":58589165748556,"sku":"ENV-40-pH","price":39215.0,"currency_code":"HUF","in_stock":true},{"title":"Include SMA to BNC adapter + $2.00","offer_id":58589165781324,"sku":"ENV-40-pH-BNC","price":39997.0,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/env-40-pH-main-2.jpg?v=1787830881"},{"product_id":"ixian-ph-transmitter","title":"Industrial pH Transmitter","description":"\u003cp\u003eDesigned with PLCs in mind, the Atlas Scientific Industrial pH transmitter is a simple to use pH transmitter that gets right to the point, reading pH.\u003c\/p\u003e\n\u003cp\u003eThe DIN rail mount and wide operating voltage make it easy to install. The 4-20mA data output and display makes it easy to read. And the simple calibration protocol gets you up and running in no time.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.001 − 14.000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/– 0.002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1, 2, 3 point (remotely though PLC or directly on board)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported probes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAny type \u0026amp; brand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemp probe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePT-100 or PT-1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuto temp compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternational standard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISO 10523 compliant (determination of pH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMount\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35mm Din rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 − 20mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9VDC − 36VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrically isolated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/pH_transmitter.pdf\" target=\"_blank\" rel=\"noopener\"\u003eIndustrial pH Transmitter Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRoHS Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/csa-certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCSA Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/atlas-scientific.com\/ph-temperature-calculator\/\" target=\"_blank\" rel=\"noopener\"\u003epH Temperature Compensation Calculator\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":58589165846860,"sku":"IND-pH","price":101970.5,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/Industrial-pH-Transmitter-main_88f0ad9d-28e2-4e71-95ab-cbf524b56cfa.jpg?v=1787830883"},{"product_id":"ixian-orp-transmitter","title":"Industrial ORP Transmitter","description":"\u003cp\u003eAnyone who has worked with PLCs knows how powerful they are. But, like anything in engineering, PLCs have their limitations. Because EZO class devices don’t integrate well with PLCs, we made the Industrial line of transmitters.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eORP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-1900.0mV − 1900.0mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/– 1mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle point (remotely though PLC or directly on board)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported probes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAny type \u0026amp; brand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuto temp compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternational standard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISO 11271 compliant (determination of redox potential)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMount\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35mm Din rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 − 20mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14VDC − 36VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrically isolated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ORP_transmitter.pdf\" target=\"_blank\" rel=\"noopener\"\u003eIndustrial ORP Transmitter Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRoHS Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/csa-certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCSA Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":58589165879628,"sku":"IND-ORP","price":101970.5,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/Industrial-ORP-Transmitter-main_144a45ad-de6e-4f74-9c1b-e50da23871a3.jpg?v=1787830883"},{"product_id":"ixian-conductivity-transmitter","title":"Industrial Conductivity Transmitter","description":"\u003cp\u003eThose of us who work with PLCs clearly understand both the power and limitations of industrial computers. Modern low voltage elections and communication protocols aren’t easily compatible with PLCs. Fortunately, the Atlas Scientific Industrial Conductivity transmitter makes it easy to get high accuracy conductivity readings on your PLC for less than half the price of comparable devices on the market today.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConductivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.07μS – 100,000μS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/– 2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 or 2 point (remotely though PLC or directly on board)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported probes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAny two lead conductivity probe (K 0.1 or K 1.0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemp probe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePT-100 or PT-1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuto temp compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternational standard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISO 7888 compliant (determination of electrical conductivity)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMount\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e35mm Din rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 − 20mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9VDC − 36VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrically isolated\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/EC_transmitter.pdf\" target=\"_blank\" rel=\"noopener\"\u003eIndustrial Conductivity Transmitter Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRoHS Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/csa-certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCSA Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":58589165912396,"sku":"IND-EC","price":129421.0,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/Industrial-Conductivity-Transmitter-main_a2f2c618-67eb-421d-ac32-ebcc35462ca8.jpg?v=1787830884"},{"product_id":"industrial-probe-tip-cap","title":"Industrial Probe Tip Cap","description":"\u003cp\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• Replacement cap for industrial pH and ORP probes\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• Works for Gen 1, 2 \u0026amp; 3 industrial probes\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• Use with pH \/ ORP probe storage solution\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":58589166043468,"sku":"IPT-C","price":5876.5,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/g3-ipt-c-main.jpg?v=1787830885"},{"product_id":"industrial-orp-probe","title":"Industrial ORP Probe","description":"\u003cp\u003eThe Atlas Scientific industrial ORP probe is built to last. It has all the sensing capabilities of our lab-grade probe in a virtually indestructible housing. The 3\/4″ NPT threaded body makes it easy to screw into a pipe, perfect for chemical production or swimming pool monitoring.\u003c\/p\u003e\n\u003cp\u003eEach probe comes with its own unique 12-digit serial number for tracking and traceability.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eUnique 12-digit serial number\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eORP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-2000mV – 2000mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/– 1mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% in 1s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensing element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlatinum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature range °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 − 99 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70m (230′)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSMA or Tinned leads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 meters (9.8′)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal temperature sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTime before recalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLife expectancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~4 Years +\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/IORP_probe.pdf\" target=\"_blank\" rel=\"noopener\"\u003eIndustrial ORP Probe Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/connecting-probes-into-a-pipe.pdf\" target=\"_blank\" rel=\"noopener\"\u003eConnecting probes into a pipe\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRoHS Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/csa-certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCSA Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ELR-No-10-2011.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEuropean legislation Regulation (EU) No 10\/2011\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ELR-No-1935-2004.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEuropean legislation Regulation (EU) No 1935\/2004\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Gen3_Industrial-ORP.zip\" target=\"_blank\" rel=\"noopener\"\u003eENV-50-ORP 3D model (*step)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"3 meters (9.8') SMA","offer_id":58589166076236,"sku":"ENV-50-ORP-SMA","price":109813.5,"currency_code":"HUF","in_stock":true},{"title":"3 meters (9.8') Tinned Lead","offer_id":58589166109004,"sku":"ENV-50-ORP-TL","price":107847.0,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/env-50-ORP-main-04_7286bf87-63d1-478a-b072-11041b8637a1.jpg?v=1787830886"},{"product_id":"industrial-conductivity-probe-k-1-0","title":"Industrial Conductivity Probe K 1.0","description":"\u003cp\u003eThe Atlas Scientific Industrial Conductivity Probe K 1.0 is a rugged, high-performance sensor designed for accurate conductivity measurements across a wide range of applications. Ideal for environments such as chemical processing and water quality monitoring, it delivers stable, reliable readings even under demanding conditions. The probe features a durable 3\/4″ NPT threaded body for easy installation and an integrated PT-1000 temperature sensor for precise temperature compensation. Its electrolyte-free design reduces maintenance needs and supports long-term operation, with calibration typically required only during installation and a lifespan that can extend up to a decade.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConductivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 − 200,000μS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/ – 2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90% in 1s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature range °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 − 100 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e141m (463 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSMA or Tinned leads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 meters (10′)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal temperature sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes (PT-1000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTime before recalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLife expectancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/IEC_probe-K1.0.pdf\" target=\"_blank\" rel=\"noopener\"\u003eIndustrial Conductivity Probe K 1.0 Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/legacy-IEC_probe-K1.0.pdf\" target=\"_blank\" rel=\"noopener\"\u003eLEGACY Industrial Conductivity Probe K 1.0 Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/connecting-probes-into-a-pipe.pdf\" target=\"_blank\" rel=\"noopener\"\u003eConnecting probes into a pipe\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRoHS Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/csa-certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCSA Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ELR-No-10-2011.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEuropean legislation Regulation (EU) No 10\/2011\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ELR-No-1935-2004.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEuropean legislation Regulation (EU) No 1935\/2004\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"SMA","offer_id":58589166338380,"sku":"ENV-50-EC-K1.0-SMA","price":121578.0,"currency_code":"HUF","in_stock":true},{"title":"Tinned Leads","offer_id":58589166371148,"sku":"ENV-50-EC-K1.0","price":117656.5,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/iec-probe-k1.0-main_05147dc7-c5d9-4781-b7b9-225b274e8526.jpg?v=1787830886"},{"product_id":"industrial-conductivity-kit-k-1-0","title":"Industrial Conductivity Kit K 1.0","description":"\u003cp\u003eAre you working with a PLC and aren’t sure what parts are right for you? Let us help you. This is the Atlas Scientific, Industrial Conductivity kit. It comes with everything you need to take high accuracy, interference-free readings with a PLC. The industrial strength conductivity probe is ready for the job, whatever it may be. This probe doesn’t care, from batch process chemical production to wastewater treatment. You can use it for anything. The DIN rail mount and wide operating voltage makes it easy to install. The 4-20mA data output and display makes it easy to read. And the simple calibration protocol gets you up and running in no time.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• 1x Industrial Conductivity Transmitter\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• 1x Industrial Conductivity Probe K 1.0\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• 2x 250ml (8oz) calibration solutions\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eK 1.0 Calibration solutions – This set includes 1 (12,880µS) and 1 (80,000µS)\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eProbe Max Pressure: 1380 kPa (200 Psi)\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eProbe Cable length: 10Ft\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eProbe Weight: 195grams\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eInternational standard: ISO 7888 compliant (determination of electrical conductivity)\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/EC_transmitter.pdf\" target=\"_blank\" rel=\"noopener\"\u003eIndustrial Conductivity Transmitter Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/IEC_probe-K1.0.pdf\" target=\"_blank\" rel=\"noopener\"\u003eIndustrial Conductivity Probe K 1.0 Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Industrial_conductivity_k1.0.pdf\" target=\"_blank\" rel=\"noopener\"\u003eIndustrial Conductivity Calibration K 1.0 Set SDS\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/legacy-IEC_probe-K1.0.pdf\" target=\"_blank\" rel=\"noopener\"\u003eLEGACY Industrial Conductivity Probe K 1.0 Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/connecting-probes-into-a-pipe.pdf\" target=\"_blank\" rel=\"noopener\"\u003eConnecting probes into a pipe\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRoHS Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/csa-certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCSA Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"I would like a Certificate of Calibration (+75.00)","offer_id":58589166436684,"sku":"KIT-106E-CoC","price":268640.0,"currency_code":"HUF","in_stock":true},{"title":"No thank you","offer_id":58589166469452,"sku":"KIT-106E","price":239234.5,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/106e-kit-main-2_f8eff82e-0e5c-43a6-af9a-6a39c07a7af0.jpg?v=1787830887"},{"product_id":"dissolved-oxygen-anti-fouling-probe-screen","title":"Dissolved Oxygen Anti-Fouling Probe Screen","description":"\u003cp\u003eCopper is a potent, naturally occurring biocide; toxic to both invertebrates and bacteria. Using a copper anti-fouling screen effectively reduces the amount of biological material that builds upon the probe. The Anti-Fouling screen lasts ~ 6 months in seawater and ~one year in freshwater.\u003c\/p\u003e\n\u003cp\u003eThis product only fits our Lab Grade Dissolved Oxygen Probe.\u003c\/p\u003e\n\u003cp\u003eThe Dissolved Oxygen Anti-Fouling Probe Screen comes with: 1x Anti-Fouling Probe Screen 1x Strip of copper tape\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• Mesh size: 22\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• Effectively reduces the amount of material that builds upon the probe\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• Lasts ~ 6 months in seawater and ~one year in freshwater\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• Fits the Atlas Scientific Lab Grade Dissolved Oxygen Probe\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/DO-AF-PS-Spec-sheet.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDissolved Oxygen Anti-Fouling Probe Screen Spec Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":58589169516876,"sku":"DO-AF-PS","price":5094.5,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/DO-Anti-Fouling-Probe-Screen-main.jpg?v=1787830926"},{"product_id":"ezo-o2-embedded-oxygen-sensor-replacement-head","title":"EZO-O2™ Replacement Head","description":"\u003cp\u003eThis product is used to replace the sensor head for the EZO-O2™ Embedded Oxygen Sensor.\u003c\/p\u003e\n\u003cp\u003e* After the new sensing head has been installed, it is important to leave the sensor head connected to the EZO-O2™ (unpowered) for 24 hours. After 24 hours, you may then issue the calibration command.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• 1x EZO-O2™ Embedded Oxygen Sensor Replacement Head\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eThis product is used to replace the sensor head for the EZO-O2™ Embedded Oxygen Sensor.\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ezo-o2-replacement-head-specsheet.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEZO-O2™ Replacement Head Specsheet\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":58589169549644,"sku":"EZO-O2-RE","price":19607.5,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/EZO-O2-RH-main.jpg?v=1787830926"},{"product_id":"ag-cl-reference-electrode","title":"Ag\/Cl Reference Electrode","description":"\u003cp\u003eThis product is designed for electrochemical researchers. To use this product correctly, you must understand half cells.\u003c\/p\u003e\n\u003cp\u003eBecause we are constantly working on new types of electrochemical technologies, we have gained vast insight into making high-quality reference cells for research. This is the only Ag\/Cl ref we use for in-house R\u0026amp;D.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• Refillable\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• High surface area Ag\/AgCl wire\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• 3 molar KCl salt concentration\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• Ceramic junction\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• Borosilicate body\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• ABS cap\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• Copper electrode connector\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• Typical output -200mV to +199mV\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• Max output when connected to S.H.E. -210mV\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/reference-electrode%20spec-sheet.pdf\" target=\"_blank\" rel=\"noopener\"\u003eAg\/Cl Reference Electrode Spec sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":58589169647948,"sku":"AC\u0026#8211;RE","price":29405.5,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/AC-RE-main_74ce6a11-babc-4de7-bcf9-0ffef75f9ce2.jpg?v=1787830927"},{"product_id":"ag-cl-reference-electrode-2","title":"Ag\/Cl Reference Electrode","description":"\u003cp\u003eThis product is designed for electrochemical researchers. To use this product correctly, you must understand half cells.\u003c\/p\u003e\n\u003cp\u003eBecause we are constantly working on new types of electrochemical technologies, we have gained vast insight into making high-quality reference cells for research. This is the only Ag\/Cl ref we use for in-house R\u0026amp;D.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• Refillable\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• High surface area Ag\/AgCl wire\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• 3 molar KCl salt concentration\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• Ceramic junction\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• Borosilicate body\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• ABS cap\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• Copper electrode connector\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• Typical output -200mV to +199mV\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• Max output when connected to S.H.E. -210mV\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/reference-electrode%20spec-sheet.pdf\" target=\"_blank\" rel=\"noopener\"\u003eAg\/Cl Reference Electrode Spec sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":58589169680716,"sku":"AC-RE","price":29405.5,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/AC-RE-main_a959bc5a-b543-4438-afd9-e7e09819307e.jpg?v=1787830928"},{"product_id":"indoor-air-quality-monitor","title":"Indoor Air Quality Monitor","description":"\u003cp\u003eIdeal for use in the home, office, factory or school, the Atlas Scientific Indoor Air Quality Monitor is essential for ensuring the health and comfort of occupants. Accurate measurements of Temperature, Humidity and Carbon Dioxide allow proactive management of any indoor environment. CO2 detection, in particular, is crucial for assessing air quality and ventilation effectiveness. Simple. Accurate. Straight to the point!\u003c\/p\u003e\n\u003cp\u003eThe Indoor Air Quality Monitor is capable of connecting to WiFi and uploading readings to Thingspeak or an MQTT service of your choice for data logging, remote monitoring or home automation.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• Displays Temperature, Humidity, and CO2\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• Real time readings\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• USB powered\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• Wall mount or table top\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/indoor-air-qauility-monitor-datasheet.pdf\" target=\"_blank\" rel=\"noopener\"\u003eIndoor Air Quality Monitor Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRoHS Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/csa-certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCSA Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":58589169844556,"sku":"IAQ-M","price":117656.5,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/iaq-main-02b.jpg?v=1787830930"},{"product_id":"pressure-sensor","title":"EZO-PRS™ Embedded Pressure Sensor","description":"\u003cp\u003eFinding a good pressure sensor can be tough. Some seem so cheap they couldn’t possibly have any meaningful accuracy, while others are so expensive, how could anyone use them? The Atlas Scientific EZO-PRS is a digital pressure sensor that provides the accuracy you need at a reasonable cost. The sensor can read the pressure of a liquid, gas, or oil from -14.7 to 65 psi.\u003c\/p\u003e\n\u003cp\u003eThe EZO-PRS™ comes with: One embedded pressure sensor, and one data cable with 5 pin male header.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCompound pressure sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003epsi (-14.7 to 65) Default\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eatm (-1 to 4.42)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ebar (-1 to 4.48)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ekPa (-101.3 to 488)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003einches of water (0 – 1,800”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ecm of water (0 – 4,570cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 reading per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 1.35% (1 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eThreaded connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/4″ NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 meter \/ 5 lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUART \u0026amp; I2C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDefault I2C address\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e106 (0x6A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eASCII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.3V − 5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWater resistant\/dust proof\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/EZO-PRS-Datasheet.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEZO-PRS™ Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRoHS Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/csa-certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCSA Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/AtlasDesktop.zip\" target=\"_blank\" rel=\"noopener\"\u003eFREE Software - AtlasDesktop Monitoring Software\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Atlasdesktop-user-guide.pdf\" target=\"_blank\" rel=\"noopener\"\u003eAtlasDesktop Monitoring Software Users Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Arduino-Uno-PRS-sample-code.pdf\" target=\"_blank\" rel=\"noopener\"\u003eArduino Uno Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Arduino-Mega-Giga-PRS-Sample-Code.pdf\" target=\"_blank\" rel=\"noopener\"\u003eArduino Mega \/ Giga Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Ardunio-I2C-PRS-sample-code.pdf\" target=\"_blank\" rel=\"noopener\"\u003eArduino I2C Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/pi_sample_code.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRaspberry Pi Sample Code (I2C)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/github.com\/Atlas-Scientific\/Ezo_uart_lib\" target=\"_blank\" rel=\"noopener\"\u003eEZO UART Library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/github.com\/Atlas-Scientific\/Ezo_I2c_lib\" target=\"_blank\" rel=\"noopener\"\u003eEZO I2C Library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/EZO-PRS-3d.zip\" target=\"_blank\" rel=\"noopener\"\u003eEZO-PRS™ 3D model (*step)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":58589201858892,"sku":"EZO-PRS","price":66665.5,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/ezo-prs-sensor-main-3.jpg?v=1787831051"},{"product_id":"color-sensor","title":"EZO-RGB™ Embedded Color Sensor – Stainless Steel Body","description":"\u003cp\u003eYour phone has a high-def camera capable of seeing everything. So, how hard could it be to accurately observe a single color and express the readings in true 8-Bit RGB or CIE? Well, as it turns out, it’s a lot harder than you may think. Although there are many different types of RGB sensors out there, the Atlas Scientific EZO-RGB-S sensor is ready to go. With a weather-resistant stainless steel housing that gives multiple mounting options, on-board illuminator LEDs and an easy to use data protocol, your machine will be detecting colors like its 1979.\u003c\/p\u003e\n\u003cp\u003eThe EZO-RGB-S™ comes with: One embedded color sensor with stainless steel body, one data cable with 5 pin male header, and one Locknut \u0026amp; O-ring.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRGB (24-bit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCIE (xyY)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLUX (0 – 65535)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOnboard LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProgrammable color matching\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBody material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e316 Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 lead data cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e400ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensing area\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15° half angle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWater resistant\/dust proof\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP67 (waterproof up to 1 meter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUART \u0026amp; I2C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDefault I2C address\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e112 (0x70)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eASCII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.3V − 5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/EZO_RGB_S_Datasheet.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEZO-RGB™ Stainless Steel Body Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.molex.com\/webdocs\/datasheets\/pdf\/en-us\/0022012057_CRIMP_HOUSINGS.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFemale connector information\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRoHS Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/csa-certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCSA Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/AtlasDesktop.zip\" target=\"_blank\" rel=\"noopener\"\u003eFREE Software - AtlasDesktop Monitoring Software\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Atlasdesktop-user-guide.pdf\" target=\"_blank\" rel=\"noopener\"\u003eAtlasDesktop Monitoring Software Users Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/EZO-RGB-how-to-view-rgb-output-on-your-computer.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHow to view RGB output on your computer\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Arduino-Uno-RGB-sample-code.pdf\" target=\"_blank\" rel=\"noopener\"\u003eArduino Uno Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Arduino-Mega-Giga-RGB-Sample-Code.pdf\" target=\"_blank\" rel=\"noopener\"\u003eArduino Mega \/ Giga Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Ardunio-I2C-RGB-sample-code.pdf\" target=\"_blank\" rel=\"noopener\"\u003eArduino I2C Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/pi_sample_code.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRaspberry Pi Sample Code (I2C)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/github.com\/Atlas-Scientific\/Ezo_uart_lib\" target=\"_blank\" rel=\"noopener\"\u003eEZO UART Library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/github.com\/Atlas-Scientific\/Ezo_I2c_lib\" target=\"_blank\" rel=\"noopener\"\u003eEZO I2C Library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/EZO-RGB.zip\" target=\"_blank\" rel=\"noopener\"\u003eEZO-RGB™ 3D model (*step)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":58589202186572,"sku":"EZO-RGB-S","price":44309.5,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/EZO-RGB-main-03.jpg?v=1787831052"},{"product_id":"co2-sensor","title":"EZO-CO2™ Research Grade CO2 Sensor","description":"\u003cp\u003eWith all the talk of Co2 these days, you would think it’s easy to detect.\u003c\/p\u003e\n\u003cp\u003eBut Co2 only consists of 0.04% of the atmosphere meaning; it’s a trace gas that’s quite difficult to detect. The Atlas Scientific EZO-CO2 Research Grade CO2 Sensor is a compact Non-Dispersive Infrared (NDIR) sensor that gets right to the point, giving you the Co2 readings in ppm. With internal temperature and humidity compensation, the Atlas Scientific EZO-CO2 sensor easily brings advanced sensing to your next project.\u003c\/p\u003e\n\u003cp\u003eThe EZO-CO2™ Research Grade CO2 Sensor comes with: One embedded carbon dioxide sensor, one data cable with 5 pin male header, and one Locknut \u0026amp; O-ring\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGaseous CO2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 − 10,000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFactory calibrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAtmosphere only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 reading per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e(+\/- 5%) + (+\/- 50 ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarmup time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 lead data cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUART \u0026amp; I2C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDefault I2C address\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105 (0x69)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eASCII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.3V − 5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLife expectancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~5.5 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/EZO_CO2_Datasheet.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEZO-CO2™ Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/0022012057_CRIMP_HOUSINGS.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFemale connector information\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.hackster.io\/atlasscientific\/arduino-co2-meter-c030ce\" target=\"_blank\" rel=\"noopener\"\u003eHow to build an Arduino CO2 meter\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRoHS Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/csa-certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCSA Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/AtlasDesktop.zip\" target=\"_blank\" rel=\"noopener\"\u003eFREE Software - AtlasDesktop Monitoring Software\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Atlasdesktop-user-guide.pdf\" target=\"_blank\" rel=\"noopener\"\u003eAtlasDesktop Monitoring Software Users Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Arduino-Uno-CO2-sample-code.pdf\" target=\"_blank\" rel=\"noopener\"\u003eArduino Uno Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Arduino-Mega-Giga-CO2-Sample-Code.pdf\" target=\"_blank\" rel=\"noopener\"\u003eArduino Mega \/ Giga Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Ardunio-I2C-CO2-sample-code.pdf\" target=\"_blank\" rel=\"noopener\"\u003eArduino I2C Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/pi_sample_code.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRaspberry Pi Sample Code (I2C)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/github.com\/Atlas-Scientific\/Ezo_uart_lib\" target=\"_blank\" rel=\"noopener\"\u003eEZO UART Library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/github.com\/Atlas-Scientific\/Ezo_I2c_lib\" target=\"_blank\" rel=\"noopener\"\u003eEZO I2C Library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/EZO-CO2.zip\" target=\"_blank\" rel=\"noopener\"\u003eEZO-CO2™ 3D model (*step)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"I would like a Certificate of Calibration (+55.00)","offer_id":58589202252108,"sku":"EZO-CO2-CoC","price":135297.5,"currency_code":"HUF","in_stock":true},{"title":"No thank you","offer_id":58589202284876,"sku":"EZO-CO2","price":113735.0,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/EZO-CO2-Main.jpg?v=1787831054"},{"product_id":"lab-grade-gold-orp-probe","title":"Lab Grade Gold ORP Probe","description":"\u003cp\u003eGold ORP probes work very well in saltwater swimming pools. This is because gold has catalytic properties different from traditional platinum ORP probes and exhibits different sensitivities to certain redox reactions. It is also reported that gold ORP probes work better in highly reducing water, such as “produced water” from oil wells, which typically has a negate (or reducing) ORP of -200mv or more.\u003c\/p\u003e\n\u003cp\u003eGold ORP probes are slightly more expensive than platinum ORP probes because binding gold to glass is more difficult and requires more energy.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eORP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-2000mV – 2000mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/– 1mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% in 1s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature range °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 − 99 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensing element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70m (230 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMale SMA \/ Male BNC (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal temperature sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTime before recalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLife expectancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 Years +\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ENV-40-ORP-G.pdf\" target=\"_blank\" rel=\"noopener\"\u003eLab Grade Gold ORP Probe Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/how-to-properly-cut-probe-cables.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHow to properly cut your probe cable\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/connecting-probes-into-a-pipe.pdf\" target=\"_blank\" rel=\"noopener\"\u003eConnecting probes into a pipe\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRoHS Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/csa-certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCSA Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ELR-No-10-2011.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEuropean legislation Regulation (EU) No 10\/2011\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ELR-No-1935-2004.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEuropean legislation Regulation (EU) No 1935\/2004\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ENV-40-ORP.zip\" target=\"_blank\" rel=\"noopener\"\u003eENV-40-ORP 3D model (*step)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"Include SMA to BNC adapter + $2.00","offer_id":58589236199756,"sku":"ENV-40-ORP-G-BNC","price":39997.0,"currency_code":"HUF","in_stock":true},{"title":"Do not include","offer_id":58589236232524,"sku":"ENV-40-ORP-G","price":39215.0,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/ENV-40-ORP-G-main-02.jpg?v=1787831107"},{"product_id":"conductivity-probe-k-0-1-copy","title":"Conductivity Probe K 0.1 – 8cm","description":"\u003cp\u003eThis Gen 2 Conductivity K 0.1 probe has a shortened cable of 8cm.\u003c\/p\u003e\n\u003cp\u003eThe Atlas Scientific line of conductivity probes has been designed to provide stable and precise readings free of fringe effect over a broad conductivity range; Because conductivity probes don’t have any electrolyte that gets depleted, they only need to be calibrated during installation.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConductivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.07 − 50,000 μS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/ – 2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90% in 1s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature range °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 − 110 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3,447 kPa (500PSI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e352m (1,157 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMale SMA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal temperature sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTime before recalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLife expectancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/l-EC_K_0.1_probe.pdf\" target=\"_blank\" rel=\"noopener\"\u003eGen 2 Conductivity Probe Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ec_soil.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHow to measure the conductivity of soil\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/how-to-properly-cut-probe-cables.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHow to properly cut your probe cable\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/connecting-probes-into-a-pipe.pdf\" target=\"_blank\" rel=\"noopener\"\u003eConnecting probes into a pipe\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRoHS Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/csa-certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCSA Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"No extension cable","offer_id":58589236330828,"sku":"ENV-40-EC-K0.1-8cm","price":31372.0,"currency_code":"HUF","in_stock":true},{"title":"3 meter extension cable","offer_id":58589236363596,"sku":"ENV-40-EC-K0.1-8cm-3m","price":37248.5,"currency_code":"HUF","in_stock":true},{"title":"7.5 meter extension cable","offer_id":58589236396364,"sku":"ENV-40-EC-K0.1-8cm-7.5m","price":43136.5,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/8cm-k0.1-main-02.jpg?v=1787831107"},{"product_id":"ezo-dissolved-oxygen-circuit","title":"EZO™ Dissolved Oxygen Circuit","description":"\u003cp\u003eUntil you’re faced with the challenge, it’s hard to see why anyone would care about dissolved oxygen. But, here you are.\u003c\/p\u003e\n\u003cp\u003eAccurately calculating the D.O. of water is quite difficult. Once all the mathematical calculations are done, it takes hundreds of chemical titration tests to confirm that the readings are correct over the full scale. The process is agonizing. Fortunately, you don’t have to do any of that. The Atlas Scientific EZO-DO Circuit gives you accurate D.O. readings in Mg\/L and percent saturation. Using its temperature, salinity, and pressure compensation features, you can be sure the readings are correct no matter where in the world you are.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDissolved Oxygen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 − 100+ mg\/L 0.1 − 400+ % saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/– 0.05 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 reading per sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported probes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAny galvanic probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 or 2 point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemp. compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSalinity compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternational standard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISO 5814 compliant (determination of dissolved oxygen)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUART \u0026amp; I2C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDefault I2C address\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e97 (0x61)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.3V − 5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eASCII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCircuit dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13.97mm x 20.16mm (0.55″ x 0.79″)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.77 grams\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/DO_EZO_Datasheet.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEZO™ Dissolved Oxygen Circuit Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/AtlasDesktop.zip\" target=\"_blank\" rel=\"noopener\"\u003eFREE Software - AtlasDesktop Monitoring Software\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Atlasdesktop-user-guide.pdf\" target=\"_blank\" rel=\"noopener\"\u003eAtlasDesktop Monitoring Software Users Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/youtu.be\/1I1Sk9pt47c\" target=\"_blank\" rel=\"noopener\"\u003eDissolved Oxygen | Common Mistakes | Air Bubble\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/youtu.be\/d9zkxkv55SE\" target=\"_blank\" rel=\"noopener\"\u003eDissolved Oxygen | Common Mistakes | Stagnant vs Moving Water\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/youtu.be\/PiXnvrTnVjs\" target=\"_blank\" rel=\"noopener\"\u003eDissolved Oxygen | Common Mistakes | Damaged Membrane\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/atlas-scientific.com\/dissolved-oxygen-calculator\" target=\"_blank\" rel=\"noopener\"\u003eDissolved Oxygen Calculator\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Arduino-Uno-DO-sample-code.pdf\" target=\"_blank\" rel=\"noopener\"\u003eArduino Uno Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Arduino-Mega-Giga-DO-Sample-Code.pdf\" target=\"_blank\" rel=\"noopener\"\u003eArduino Mega \/ Giga Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Ardunio-I2C-DO-sample-code.pdf\" target=\"_blank\" rel=\"noopener\"\u003eArduino I2C Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/pi_sample_code.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRaspberry Pi Sample Code (UART, I2C, USB)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/github.com\/Atlas-Scientific\/Ezo_uart_lib\" target=\"_blank\" rel=\"noopener\"\u003eEZO UART Library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/github.com\/Atlas-Scientific\/Ezo_I2c_lib\" target=\"_blank\" rel=\"noopener\"\u003eEZO I2C Library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.instructables.com\/id\/UART-AND-I2C-MODE-SWITCHING-FOR-ATLAS-SCIENTIFIC-E\/\" target=\"_blank\" rel=\"noopener\"\u003eUART and I2C mode switching\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ezo-do-Wiringdiagram.pdf\" target=\"_blank\" rel=\"noopener\"\u003eWiring Diagram\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRoHS Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/csa-certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCSA Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/dissolved_oxygen-footprint.zip\" target=\"_blank\" rel=\"noopener\"\u003eEZO™ Dissolved Oxygen Circuit Footprint File (*.dxf)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/EZO-DO.zip\" target=\"_blank\" rel=\"noopener\"\u003eEZO™ Dissolved Oxygen Circuit 3D model (*step)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":58589269590348,"sku":"EZO-DO","price":21171.5,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/EZO-Dissolved-Oxygen-Circuit-main.jpg?v=1787831156"},{"product_id":"ezo-conductivity-circuit","title":"EZO™ Conductivity Circuit","description":"\u003cp\u003eFrom chemical production to hydroponics, conductivity is a fundamental measurement of water chemistry. The Atlas Scientific EZO-EC Circuit reads conductivity, salinity, and TDS (PPM). Embedding this module into your machine gives you access to the same accuracy and functionality found in costly bench-top conductivity meters. If you need accurate readings that you can rely on, the EZO-EC circuit is the drop-in solution you have been looking for.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConductivity = μS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTotal dissolved solids = ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSalinity = PSU 0.00 – 42.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpecific gravity (sea water only) = 1.00 – 1.300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.07 − 500,000+ μS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/ – 2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEC reading time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e600ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported probes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK 0.01 – K 10.2 any brand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 or 3 point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemp. compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternational standard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eISO 7888 compliant (determination of electrical conductivity)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUART \u0026amp; I2C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDefault I2C address\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 (0x64)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.3V − 5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eASCII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCircuit dimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13.97mm x 20.16mm (0.55″ x 0.79″)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.77 grams\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/EC_EZO_Datasheet.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEZO™ Conductivity Circuit Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/conductivity_accuracy_graph.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEZO™ Conductivity Accuracy Graph\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ezo-ec-wiringdiagram.pdf\" target=\"_blank\" rel=\"noopener\"\u003eConductivity Wiring Diagram\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRoHS Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/csa-certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCSA Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/AtlasDesktop.zip\" target=\"_blank\" rel=\"noopener\"\u003eFREE Software - AtlasDesktop Monitoring Software\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Atlasdesktop-user-guide.pdf\" target=\"_blank\" rel=\"noopener\"\u003eAtlasDesktop Monitoring Software Users Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Arduino-Uno-EC-sample-code.pdf\" target=\"_blank\" rel=\"noopener\"\u003eArduino Uno Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Arduino-Mega-Giga-EC-Sample-Code.pdf\" target=\"_blank\" rel=\"noopener\"\u003eArduino Mega \/ Giga Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Ardunio-I2C-EC-sample-code.pdf\" target=\"_blank\" rel=\"noopener\"\u003eArduino I2C Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/pi_sample_code.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRaspberry Pi Sample Code (UART, I2C, USB)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/EC-EZO-footprint.zip\" target=\"_blank\" rel=\"noopener\"\u003eEZO™ Conductivity Circuit Footprint File (*.dxf)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/EZO-EC.zip\" target=\"_blank\" rel=\"noopener\"\u003eEZO™ Conductivity Circuit 3D model (*step)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/github.com\/Atlas-Scientific\/Ezo_uart_lib\" target=\"_blank\" rel=\"noopener\"\u003eEZO UART Library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/github.com\/Atlas-Scientific\/Ezo_I2c_lib\" target=\"_blank\" rel=\"noopener\"\u003eEZO I2C Library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.instructables.com\/id\/MAKE-YOUR-OWN-PH-EC-MONITOR-WITH-LED-INDICATORS\/\" target=\"_blank\" rel=\"noopener\"\u003epH and Salinity Monitoring System with LEDs\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.instructables.com\/id\/UART-AND-I2C-MODE-SWITCHING-FOR-ATLAS-SCIENTIFIC-E\/\" target=\"_blank\" rel=\"noopener\"\u003eUART and I2C mode switching\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.instructables.com\/id\/AUTOMATIC-TEMPERATURE-COMPENSATION-OF-THE-EZO-EC-S\/\" target=\"_blank\" rel=\"noopener\"\u003eAuto Temp Compensation for Conductivity\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":58589269623116,"sku":"EZO-EC","price":26668.5,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/EZO-Conductivity-Circuit-main.jpg?v=1787831156"},{"product_id":"co2-scrubber","title":"Co2 Scrubber","description":"\u003cp\u003eAdding Co2 into a closed system is easy, but removing it can be tricky. We have been using Co2 scrubbers for years and didn’t think much of it. After receiving many requests over the years, we finally decided to make a simple Co2 scrubber that anyone can use. It’s a straightforward design that just works.\u003c\/p\u003e\n\u003cp\u003eThis Co2 scrubber works fast. With an airflow rate of just 6 LPM, the Co2 is reduced by ~1,000 ppm. The total amount of Co2 the scrubber can absorb is ~360 liters of pure Co2.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection port\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e¾” female NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAbsorption material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eColor changing soda lime\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmount of material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 lbs (1.3 Kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCo2 absorption capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~240-360 liters of Co2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAbsorption rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000 ppm @ 6 LPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 psi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.7 lbs (3.5kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEmpty weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.2 lbs (1.9kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Co2-scubber-spec-sheet.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCo2 Scrubber Spec Sheet\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":58589271916876,"sku":"CO2-SBR","price":66665.5,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/Co2-Scubber-Main-1.jpg?v=1787831172"},{"product_id":"industrial-dissolved-oxygen-membrane-replacement-kit","title":"Industrial Dissolved Oxygen Membrane Replacement Kit","description":"\u003cp\u003eThe silicone membrane used in the Atlas Scientific Industrial Dissolved Oxygen probe is tough, but nothing lasts forever. If your Dissolved Oxygen membrane starts cracking or it ruptures, don’t buy a new probe; just replace it with this kit.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• 2x 20ml Zero Dissolved Oxygen calibration solution pouches\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• 1x Industrial Dissolved Oxygen probe replacement cap\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• 1x Bottle of replacement electrolyte solution\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Dissolved-Oxygen-Solution-SDS.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDissolved Oxygen Calibration Solution SDS\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Dissolved-Oxygen-Electrolyte-Solution-SDS.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDissolved Oxygen Electrolyte Solution SDS\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":58589272113484,"sku":"Kit-104D","price":29808.0,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/Kit-104D-main-2.jpg?v=1787831174"},{"product_id":"mini-conductivity-k-1-0-kit","title":"Mini Conductivity K 1.0 Kit","description":"\u003cp\u003eIf you are new to electrochemical sensing, knowing what components you need can get confusing. Let us help you. The Atlas Scientific Mini K1 EZO- Conductivity Kit is perfect measuring water with a conductivity range from 10µs to 100,000µs. That means this kit is perfect for environmental monitoring, hydroponics, and both freshwater and saltwater aquariums.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• 1x EZO™ Conductivity Circuit\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• 1x Mini Conductivity Probe: 5 µS\/cm to 200,000 µS\/cm\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• 1x Electrically Isolated EZO™ Carrier Board\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• 4x 20ml calibration solution pouches (2x 12,880µS and 2x 80,000µS)\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eCarrier Board dimensions\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e56.2mm x 32mm (2.2″ x 1.2″)\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eWeight: 25 grams\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/EC_EZO_Datasheet.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEZO™ Conductivity Circuit Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Mini_EC_K_1.0_probe.pdf\" target=\"_blank\" rel=\"noopener\"\u003eMini Conductivity Probe K 1.0 Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/electrically-isolated-ezo-carrier-board.pdf\" target=\"_blank\" rel=\"noopener\"\u003eElectrically Isolated EZO™ Carrier Board Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/conductivity_accuracy_graph.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEZO™ Conductivity Accuracy Graph\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ezo-ec-wiringdiagram.pdf\" target=\"_blank\" rel=\"noopener\"\u003eWiring Diagram\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/connecting-probes-into-a-pipe.pdf\" target=\"_blank\" rel=\"noopener\"\u003eConnecting probes into a pipe\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/how-to-properly-cut-probe-cables.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHow to properly cut your probe cable\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRoHS Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/csa-certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCSA Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/AtlasDesktop.zip\" target=\"_blank\" rel=\"noopener\"\u003eFREE Software - AtlasDesktop Monitoring Software\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Atlasdesktop-user-guide.pdf\" target=\"_blank\" rel=\"noopener\"\u003eAtlasDesktop Monitoring Software Users Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Arduino-Uno-EC-sample-code.pdf\" target=\"_blank\" rel=\"noopener\"\u003eArduino Uno Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Arduino-Mega-Giga-EC-Sample-Code.pdf\" target=\"_blank\" rel=\"noopener\"\u003eArduino Mega \/ Giga Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Ardunio-I2C-EC-sample-code.pdf\" target=\"_blank\" rel=\"noopener\"\u003eArduino I2C Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/pi_sample_code.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRaspberry Pi Sample Code (UART, I2C, USB)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/EC-EZO-footprint.zip\" target=\"_blank\" rel=\"noopener\"\u003eConductivity CAD Footprint File (*.dxf)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/github.com\/Atlas-Scientific\/Ezo_uart_lib\" target=\"_blank\" rel=\"noopener\"\u003eEZO UART Library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/github.com\/Atlas-Scientific\/Ezo_I2c_lib\" target=\"_blank\" rel=\"noopener\"\u003eEZO I2C Library\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":58589282664780,"sku":"M-EC-KIT-1.0","price":78430.0,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/M-EC-KIT-1.0-main.jpg?v=1787831178"},{"product_id":"orp-storage-3-pouches","title":"ORP Storage Solution Set (3 pouches)","description":"\u003cp\u003eAtlas Scientific pH\/ORP storage solution is about as exciting as it gets!\u003c\/p\u003e\n\u003cp\u003eThis 3 molar KCl solution is packed with Kathon GC preservative and topped off with a dash of potassium phthalate. If you are looking to enter the exciting world of long term probe storage, look no further than Atlas Scientific pH\/ORP storage solution.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• 3x ORP Probe Storage Solution\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• 20ml each pouch\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• Standardized against NIST-certified references\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• 2 year shelf life at room temperature\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ORP-Storage-SDS.pdf\" target=\"_blank\" rel=\"noopener\"\u003eORP Probe Storage Solution SDS\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":58589283942732,"sku":"ASPHSP-O-3","price":3921.5,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/pH-storage-pouches-main.jpg?v=1787831180"},{"product_id":"humidity-sensor","title":"EZO-HUM™ Embedded Humidity Probe – Stainless Steel Body","description":"\u003cp\u003eFrom industrial processes to environmental monitoring, this humidity probe can be used in countless applications. Our stainless steel Humidity Probe is versatile and durable; Ideal for both indoor and outdoor humidity monitoring. The EZO Embedded Humidity Probe gives the same readings as our EZO-HUM Circuit. There is no difference in the readings or accuracy, only the design.\u003c\/p\u003e\n\u003cp\u003eThis probe comes fully calibrated and ready to use right out of the box.\u003c\/p\u003e\n\u003cp\u003eThe EZO-HUM-P-S™ comes with: One embedded Humidity probe with stainless steel body, one data cable with 5 pin male header, and one Locknut \u0026amp; O-ring.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRelative humidity (RH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDew point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAir temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 – 100% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFactory calibrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 reading per second (UART mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 reading per 300 milliseconds (I2C mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 2% of reading from 5-95% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBody material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e316 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 lead data cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUART \u0026amp; I2C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDefault I2C address\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e111 (0x6F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eASCII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.3V − 5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIP rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP67 (waterproof up to 1 meter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNEMA rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLife expectancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/EZO-HUM-P-S-Datasheet.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEZO-HUM™ Stainless Steel Body Probe Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.molex.com\/webdocs\/datasheets\/pdf\/en-us\/0022012057_CRIMP_HOUSINGS.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFemale connector information\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRoHS Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/csa-certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCSA Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/AtlasDesktop.zip\" target=\"_blank\" rel=\"noopener\"\u003eFREE Software - AtlasDesktop Monitoring Software\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Atlasdesktop-user-guide.pdf\" target=\"_blank\" rel=\"noopener\"\u003eAtlasDesktop Monitoring Software Users Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Arduino-Uno-HUM-sample-code.pdf\" target=\"_blank\" rel=\"noopener\"\u003eArduino Uno Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Arduino-Mega-Giga-HUM-Sample-Code.pdf\" target=\"_blank\" rel=\"noopener\"\u003eArduino Mega \/ Giga Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Ardunio-I2C-HUM-sample-code.pdf\" target=\"_blank\" rel=\"noopener\"\u003eArduino I2C Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/pi_sample_code.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRaspberry Pi Sample Code (I2C)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/github.com\/Atlas-Scientific\/Ezo_uart_lib\" target=\"_blank\" rel=\"noopener\"\u003eEZO UART Library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/github.com\/Atlas-Scientific\/Ezo_I2c_lib\" target=\"_blank\" rel=\"noopener\"\u003eEZO I2C Library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/EZO-Hum.zip\" target=\"_blank\" rel=\"noopener\"\u003eEZO-HUM™ 3D model (*step)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":58589301768524,"sku":"EZO-HUM-P-S","price":41181.5,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/ezo-humidity-main.jpg?v=1787831210"},{"product_id":"oxygen-sensor","title":"EZO-O2™ Embedded Oxygen Sensor – Stainless Steel Body","description":"\u003cp\u003eThe Atlas Scientific gaseous oxygen sensor features a durable stainless steel enclosure, offering accurate measurements of oxygen concentrations from 0 to 420 ppt for both environmental monitoring and industrial applications. Pre-calibrated for immediate use, its stainless steel design guarantees resilience and dependable performance in tough conditions.\u003c\/p\u003e\n\u003cp\u003eThe EZO-O2-S™ comes with: One embedded oxygen sensor with stainless steel body, one data cable with 5 pin male header, and one Locknut \u0026amp; O-ring.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGaseous O2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 – 42% (2x atmospheric O2 levels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFactory calibrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAtmosphere only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 reading per second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.01% (0.2 PPT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBody material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e316 Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 lead data cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUART \u0026amp; I2C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDefault I2C Address\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e108 (0x6c)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eASCII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.3V – 5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLife expectancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~3.5 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/EZO-O2-S-datasheet.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEZO-O2™ Stainless Steel Body Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/0022012057_CRIMP_HOUSINGS.pdf\" target=\"_blank\" rel=\"noopener\"\u003eFemale connector information\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRoHS Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/csa-certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCSA Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/AtlasDesktop.zip\" target=\"_blank\" rel=\"noopener\"\u003eFREE Software - AtlasDesktop Monitoring Software\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Atlasdesktop-user-guide.pdf\" target=\"_blank\" rel=\"noopener\"\u003eAtlasDesktop Monitoring Software Users Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Arduino-Uno-O2-sample-code.pdf\" target=\"_blank\" rel=\"noopener\"\u003eArduino Uno Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Arduino-Mega-Giga-O2-Sample-Code.pdf\" target=\"_blank\" rel=\"noopener\"\u003eArduino Mega \/ Giga Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Ardunio-I2C-O2-sample-code.pdf\" target=\"_blank\" rel=\"noopener\"\u003eArduino I2C Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/pi_sample_code.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRaspberry Pi Sample Code (I2C)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/github.com\/Atlas-Scientific\/Ezo_uart_lib\" target=\"_blank\" rel=\"noopener\"\u003eEZO UART Library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/github.com\/Atlas-Scientific\/Ezo_I2c_lib\" target=\"_blank\" rel=\"noopener\"\u003eEZO I2C Library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/EZO-O2.zip\" target=\"_blank\" rel=\"noopener\"\u003eEZO-O2™ 3D model (*step)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":58589301801292,"sku":"EZO-O2-S","price":58822.5,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/EZO-O2-main.jpg?v=1787831211"},{"product_id":"mini-orp-probe","title":"Mini Lab Grade ORP Probe","description":"\u003cp\u003eAll Atlas Scientific mini probes have the same capabilities as our full-size lab grade probes, just smaller. And if space is an issue, the Atlas Scientific mini lab grade ORP probe might be for you. This probe is great for environmental monitoring applications where the probes need to be hidden or in machines with limited space.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eORP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-2000mV – 2000mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/– 1mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% in 1s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature range °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 − 99 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e78m (254 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMale SMA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal temperature sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTime before recalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLife expectancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~2 Years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/mini-orp-probe.pdf\" target=\"_blank\" rel=\"noopener\"\u003eMini Lab Grade ORP Probe Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/how-to-properly-cut-probe-cables.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHow to properly cut probe cables\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/connecting-probes-into-a-pipe.pdf\" target=\"_blank\" rel=\"noopener\"\u003eConnecting probes into a pipe\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRoHS Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/csa-certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCSA Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ELR-No-10-2011.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEuropean legislation Regulation (EU) No 10\/2011\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ELR-No-1935-2004.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEuropean legislation Regulation (EU) No 1935\/2004\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ENV-20-ORP.zip\" target=\"_blank\" rel=\"noopener\"\u003eENV-20-ORP 3D model (*step)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":58589301866828,"sku":"ENV-20-ORP","price":39215.0,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/mini-orp-probe-main-02.jpg?v=1787831212"},{"product_id":"orp-probe","title":"Lab Grade ORP Probe","description":"\u003cp\u003eLab grade probes are designed to give the highest accuracy readings possible. The probes chemically inert body lets you expose it to fluorinated compounds and other powerful oxidizers or reducers that would normally destroy an ORP probe of lesser quality. The Atlas Scientific lab-grade ORP probe delivers reliable readings in whatever bizarre chemical you have made.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eORP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-2000mV – 2000mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/– 1mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% in 1s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature range °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 − 99 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSensing element\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePlatinum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70m (230 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMale SMA \/ Male BNC (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal temperature sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTime before recalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLife expectancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 Years +\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/orp_probe.pdf\" target=\"_blank\" rel=\"noopener\"\u003eLab Grade ORP Probe Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/how-to-properly-cut-probe-cables.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHow to properly cut your probe cable\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/connecting-probes-into-a-pipe.pdf\" target=\"_blank\" rel=\"noopener\"\u003eConnecting probes into a pipe\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRoHS Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/csa-certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCSA Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ELR-No-10-2011.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEuropean legislation Regulation (EU) No 10\/2011\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ELR-No-1935-2004.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEuropean legislation Regulation (EU) No 1935\/2004\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ENV-40-ORP.zip\" target=\"_blank\" rel=\"noopener\"\u003eENV-40-ORP 3D model (*step)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"Include SMA to BNC adapter + $2.00","offer_id":58589301899596,"sku":"ENV-40-ORP-BNC","price":36075.5,"currency_code":"HUF","in_stock":true},{"title":"Do not include","offer_id":58589301932364,"sku":"ENV-40-ORP","price":35293.5,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/G2Lab-Grade-ORP-probe-main-02.jpg?v=1787831212"},{"product_id":"spear-tip-ph-probe","title":"Spear Tip \/ Soil pH Probe","description":"\u003cp\u003eA spear tipped pH probe is good for stabbing things. It works great for reading the pH of soil or food.\u003c\/p\u003e\n\u003cp\u003eThe tip is a solid glass point that seems almost unbreakable. Unless you are pounding this probe into the ground like a tent stake, the tip will not break. Although the Atlas Scientific spear tip probe looks diffident, it can read pH just as well as our lab-grade pH probe.\u003c\/p\u003e\n\u003cp\u003eThis probe is all about its shape, it is intended (but not required) to be used to pierce into a material.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eSilver \/ silver chloride\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 − 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/– 0.002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% in 1s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature range °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 − 110 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70m (230′)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMale SMA \/ Male BNC (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal temperature sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTime before recalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~1 Year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLife expectancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~2.5 Years +\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/spear_tip_pH_probe.pdf\" target=\"_blank\" rel=\"noopener\"\u003eSpear Tip pH Probe Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/how-to-properly-cut-probe-cables.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHow to properly cut probe cables\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/connecting-probes-into-a-pipe.pdf\" target=\"_blank\" rel=\"noopener\"\u003eConnecting probes into a pipe\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRoHS Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/csa-certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCSA Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ELR-No-10-2011.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEuropean legislation Regulation (EU) No 10\/2011\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ELR-No-1935-2004.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEuropean legislation Regulation (EU) No 1935\/2004\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/atlas-scientific.com\/ph-temperature-calculator\/\" target=\"_blank\" rel=\"noopener\"\u003epH Temperature Compensation Calculator\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ENV-45-pH.zip\" target=\"_blank\" rel=\"noopener\"\u003eENV-45-pH 3D model (*step)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"Include SMA to BNC adapter + $2.00","offer_id":58589301965132,"sku":"ENV-45-pH-BNC","price":67447.5,"currency_code":"HUF","in_stock":true},{"title":"Do not include","offer_id":58589301997900,"sku":"ENV-45-pH","price":66665.5,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/ENV-45-pH-main.jpg?v=1787831213"},{"product_id":"micro-orp-probe","title":"Micro ORP Probe","description":"\u003cp\u003eThe Atlas Scientific Micro-ORP Probe was designed for microfluidics and other small applications. Because the probe is so small, it had to be built as a half cell ORP probe. A ½ cell probe works just like a normal ORP probe, but it consists of two separate pieces, the working electrode, and the reference electrode. The supplied connector board merges the two halves into one, just like a normal ORP probe.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• 1 Micro ORP Probe\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• 1 Micro Reference Probe\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• 1 Half Cell SMA Breakout Board\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eORP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-2000mV – 2000mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/– 1mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% in 1s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature range °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 − 90 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e150 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60m (197 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMale SMA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e61cm (2′)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal temperature sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTime before recalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~1 month\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLife expectancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~6 − 12 months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/micro_ORP_probe.pdf\" target=\"_blank\" rel=\"noopener\"\u003eMirco ORP Probe Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRoHS Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/csa-certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCSA Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ELR-No-10-2011.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEuropean legislation Regulation (EU) No 10\/2011\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ELR-No-1935-2004.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEuropean legislation Regulation (EU) No 1935\/2004\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"No thanks, I have one","offer_id":58589302063436,"sku":"ENV-10-ORP","price":95691.5,"currency_code":"HUF","in_stock":true},{"title":"Yes, I need an adapter","offer_id":58589302096204,"sku":"ENV-10-ORP-SMA-HCA","price":98037.5,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/Micro-ORP-Probe-main-1.jpg?v=1787831214"},{"product_id":"mini-d-o-probe","title":"Mini Lab Grade Dissolved Oxygen Probe","description":"\u003cp\u003eThe Atlas Scientific Mini Lab Grade Dissolved Oxygen probe is one of many unique products you will only find at Atlas Scientific. Designed for small spaces, this small probe gives you the same quality readings found in our lab-grade Dissolved Oxygen just smaller. Because smaller probes use fewer precious metals, we can get the price lower. Keep in mind; smaller probes hold less electrolyte. Because of this, they need to be refilled more frequently than full-size or industrial probes.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDissolved Oxygen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 − 50 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/– 0.2 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~0.5 mg\/L\/per sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature range °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 − 50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e689 kPa (100PSI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70m (230′)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMale SMA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 meter (3.2′)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal temperature sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTime before recalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~6 Months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLife expectancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 Years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaintenance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~6 Months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eIncluded with Mini Dissolved Oxygen probe\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e1x Syringe\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e1x 30ml bottle of Electrolyte Solution\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Mini_DO_probe.pdf\" target=\"_blank\" rel=\"noopener\"\u003eMini Lab Grade Dissolved Oxygen Probe Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/how-to-properly-cut-probe-cables.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHow to properly cut your probe cable\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/connecting-probes-into-a-pipe.pdf\" target=\"_blank\" rel=\"noopener\"\u003eConnecting probes into a pipe\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRoHS Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/csa-certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCSA Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ELR-No-10-2011.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEuropean legislation Regulation (EU) No 10\/2011\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ELR-No-1935-2004.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEuropean legislation Regulation (EU) No 1935\/2004\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ENV-20-DO.zip\" target=\"_blank\" rel=\"noopener\"\u003eENV-20-DOX 3D model (*step)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/youtu.be\/1I1Sk9pt47c\" target=\"_blank\" rel=\"noopener\"\u003eDissolved Oxygen | Common Mistakes | Air Bubble\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/youtu.be\/d9zkxkv55SE\" target=\"_blank\" rel=\"noopener\"\u003eDissolved Oxygen | Common Mistakes | Stagnant vs Moving Water\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/youtu.be\/PiXnvrTnVjs\" target=\"_blank\" rel=\"noopener\"\u003eDissolved Oxygen | Common Mistakes | Damaged Membrane\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":58589302227276,"sku":"ENV-20-DOX","price":78430.0,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/mini-lab-grade-do-main.jpg?v=1787831216"},{"product_id":"conductivity-k-10-kit","title":"Conductivity K 10 Kit","description":"\u003cp\u003eIf you are new to electrochemical sensing, knowing what components you need can get confusing. Let us help you. The Atlas Scientific K10 EZO- Conductivity Kit is perfect measuring water with a conductivity range from 70µs to 500,000+µs. This kit is perfect for saltwater and chemical process monitoring.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• 1x EZO™ Conductivity Circuit\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• 1x Conductivity Probe: 10 µS\/cm to 1S\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• 1x Electrically Isolated EZO™ Carrier Board\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e• 2x 125ml (4oz) calibration solutions\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eK 10 – This set includes 1 (12,880µS) and 1 (150,000µS)\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eCarrier Board dimensions\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003e56.2mm x 32mm (2.2″ x 1.2″)\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd colspan=\"2\"\u003eWeight: 25 grams\u003c\/td\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/EC_EZO_Datasheet.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEZO™ Conductivity Circuit Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/EC_K_10_probe.pdf\" target=\"_blank\" rel=\"noopener\"\u003eConductivity Probe K 10 Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/conductivity_accuracy_graph.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEZO™ Conductivity Accuracy Graph\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ezo-ec-wiringdiagram.pdf\" target=\"_blank\" rel=\"noopener\"\u003eWiring Diagram\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/connecting-probes-into-a-pipe.pdf\" target=\"_blank\" rel=\"noopener\"\u003eConnecting probes into a pipe\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/how-to-properly-cut-probe-cables.pdf\" target=\"_blank\" rel=\"noopener\"\u003eHow to properly cut your probe cable\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRoHS Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/csa-certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCSA Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/AtlasDesktop.zip\" target=\"_blank\" rel=\"noopener\"\u003eFREE Software - AtlasDesktop Monitoring Software\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Atlasdesktop-user-guide.pdf\" target=\"_blank\" rel=\"noopener\"\u003eAtlasDesktop Monitoring Software Users Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Arduino-Uno-EC-sample-code.pdf\" target=\"_blank\" rel=\"noopener\"\u003eArduino Uno Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Arduino-Mega-Giga-EC-Sample-Code.pdf\" target=\"_blank\" rel=\"noopener\"\u003eArduino Mega \/ Giga Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/Ardunio-I2C-EC-sample-code.pdf\" target=\"_blank\" rel=\"noopener\"\u003eArduino I2C Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/pi_sample_code.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRaspberry Pi Sample Code (UART, I2C, USB)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/EC-EZO-footprint.zip\" target=\"_blank\" rel=\"noopener\"\u003eConductivity CAD Footprint File (*.dxf)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/github.com\/Atlas-Scientific\/Ezo_uart_lib\" target=\"_blank\" rel=\"noopener\"\u003eEZO UART Library\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/github.com\/Atlas-Scientific\/Ezo_I2c_lib\" target=\"_blank\" rel=\"noopener\"\u003eEZO I2C Library\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":58589302325580,"sku":"EC-KIT-10","price":95300.5,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/EC-KIT-10-main.jpg?v=1787831218"},{"product_id":"conductivity-oem-circuit","title":"Conductivity OEM™ Circuit","description":"\u003cp\u003eDesigned for mass production, the OEM-EC Circuit lets engineers add laboratory-grade conductivity measurements to any product. Because it can work with any off the shelf conductivity probe, you have the freedom to design a system that meets the needs of your customers without having to use expensive probes or connectors.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConductivity Total dissolved solids (ppm) Salinity = PSU (ppt) 0.00 − 42.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.07 − 500,000+ μS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/ – 2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 reading every 640ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported probes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eK 0.01 – K 600 any brand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 or 2 point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemp compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSMBus\/I2C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDefault I2C address\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0x64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.0V − 5.5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData format\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eASCII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12mm x 11mm (0.47″ x 0.43″)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.53 grams\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/EC_oem_datasheet.pdf\" target=\"_blank\" rel=\"noopener\"\u003eConductivity OEM™ Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/oem-dev-board.pdf\" target=\"_blank\" rel=\"noopener\"\u003eOEM Simple Development Board Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRoHS Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/csa-certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCSA Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/oem-ec-sample-code.pdf\" target=\"_blank\" rel=\"noopener\"\u003eConductivity OEM™ Arduino Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/github.com\/Atlas-Scientific\/python_AtlasOEM_lib\" target=\"_blank\" rel=\"noopener\"\u003eConductivity OEM™ Raspberry Pi Sample Code\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/OEM-footprint.rar\" target=\"_blank\" rel=\"noopener\"\u003eConductivity OEM™ Footprint File (*.dxf)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/EC_OEM.zip\" target=\"_blank\" rel=\"noopener\"\u003eConductivity OEM™ 3D model (*step)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"Default Title","offer_id":58589428449612,"sku":"EC-OEM","price":3921.5,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/EC-OEM-main.jpg?v=1787831413"}],"url":"https:\/\/waterscopeiot.com\/collections\/meroszondak-es-szenzorok.oembed?page=4","provider":"WaterScope IoT store","version":"1.0","type":"link"}