{"product_id":"industrial-conductivity-probe-k-1-0","title":"Industrial Conductivity Probe K 1.0","description":"\u003cp\u003eThe Atlas Scientific Industrial Conductivity Probe K 1.0 is a rugged, high-performance sensor designed for accurate conductivity measurements across a wide range of applications. Ideal for environments such as chemical processing and water quality monitoring, it delivers stable, reliable readings even under demanding conditions. The probe features a durable 3\/4″ NPT threaded body for easy installation and an integrated PT-1000 temperature sensor for precise temperature compensation. Its electrolyte-free design reduces maintenance needs and supports long-term operation, with calibration typically required only during installation and a lifespan that can extend up to a decade.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable class=\"product-specs\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReads\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConductivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 − 200,000μS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e+\/ – 2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResponse time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90% in 1s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature range °C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 − 100 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax depth\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e141m (463 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSMA or Tinned leads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3 meters (10′)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInternal temperature sensor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes (PT-1000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTime before recalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLife expectancy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e~10 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eDocuments \u0026amp; downloads\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/IEC_probe-K1.0.pdf\" target=\"_blank\" rel=\"noopener\"\u003eIndustrial Conductivity Probe K 1.0 Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/legacy-IEC_probe-K1.0.pdf\" target=\"_blank\" rel=\"noopener\"\u003eLEGACY Industrial Conductivity Probe K 1.0 Datasheet\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/connecting-probes-into-a-pipe.pdf\" target=\"_blank\" rel=\"noopener\"\u003eConnecting probes into a pipe\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/RoHS-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eRoHS Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/CE-Certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCE Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/csa-certificate.pdf\" target=\"_blank\" rel=\"noopener\"\u003eCSA Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ELR-No-10-2011.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEuropean legislation Regulation (EU) No 10\/2011\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/files.atlas-scientific.com\/ELR-No-1935-2004.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEuropean legislation Regulation (EU) No 1935\/2004\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Atlas Scientific","offers":[{"title":"SMA","offer_id":58589166338380,"sku":"ENV-50-EC-K1.0-SMA","price":121578.0,"currency_code":"HUF","in_stock":true},{"title":"Tinned Leads","offer_id":58589166371148,"sku":"ENV-50-EC-K1.0","price":117656.5,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1085\/6248\/1484\/files\/iec-probe-k1.0-main_05147dc7-c5d9-4781-b7b9-225b274e8526.jpg?v=1787830886","url":"https:\/\/waterscopeiot.com\/products\/industrial-conductivity-probe-k-1-0","provider":"WaterScope IoT store","version":"1.0","type":"link"}